摘要
随着智能化变电站的建设,全光纤电流互感器得到广泛应用。由于其与常规电流互感器的工作原理不同,如何对其在现场进行有效的检验测试是一个难题。叙述了全光纤电流互感器的工作原理,并对其故障特征和检测项目进行分析。介绍了一种利用大电容放电原理制作的便携式现场测试装置,通过对上海110kV封周变电站全光纤电流互感器的现场试验,证明了测试原理与系统是有效的。
With the construction of intelligent substation,FOCT(fiber optical current transducer)has been widely used.For the working principle of FOCT is different from the conventional current transducer,the effective inspection and testing was a problem.The author introduces the working principle of FOCT,analysis of the fault feature and test items.And The author describes a portable testing device,which was made by the principle of large capacitor discharge.And the field test results in the FENGZHOU Transformer substation proved the test principle and system effectiveness.
出处
《电力与能源》
2013年第1期30-33,共4页
Power & Energy
关键词
全光纤电流互感器
故障特征
测试装置
大电容放电
FOCT(Fiber optical current transducer)
Fault feature
Test device
Large capacitor discharge