摘要
目的:初步探讨低温等离子射频消融术在早期喉癌治疗中的应用及近期疗效。方法:对我科6例早期声带癌患者(Tla 5例、Tlb 1例)在全身麻醉、支撑喉镜下行低温等离子射频消融术,观察肿瘤的切除效果及复发情况。结果:所有患者术后发声良好,声门区结构保存好。随访6~12个月未见局部复发和淋巴结转移。结论:尽管低温等离子射频消融术目前在恶性肿瘤切除术中使用较少,但此技术对选择性部分早期喉癌的近期疗效是肯定的,值得进一步探讨。
Objective: To investigate the impact of radiofrequency coblation for the treatment of T1 glottic cancer. Method: Six patients with early-stage glottic cancer(Tla= 5, Tlb=1 ) treated with coblation were enrolled in this study. The outcome of the surgery were analyzed. Result: No complication happened during the follow-up of 6 to 12 months. All patients achieved satisfactory post-operative voice. Conclusion: Although current probe design limits the potential /'or resection of some tumors, radiofrequency coblation appears to be an attractive evolving technique for the endoscopic resection of selected glottic cancer.
出处
《临床耳鼻咽喉头颈外科杂志》
CAS
北大核心
2013年第3期153-154,共2页
Journal of Clinical Otorhinolaryngology Head And Neck Surgery