摘要
介绍核安全三级(DEL)水冷式冷水机组的开发过程,详述其蒸发器和冷凝器的热力计算、强度计算以及应力分析与评定、整机试验及试验程序。
The development process of the nuclear safety class 3(DEL) water-cooled chiller is introduced.Thermodynamic calculation,strength calculation,stress analysis and assessment,the unit test and its procedure of its evaporator and condenser are described in detail.
出处
《制冷与空调》
2012年第6期24-27,72,共5页
Refrigeration and Air-Conditioning
关键词
核安全三级
水冷式冷水机组
抗震
应力分析与评定
nuclear safety class 3
water-cooled chiller
anti-seismic
stress analysis and assessment