期刊文献+

高压断路器二次回路断路测量方法应用综述 被引量:9

Application Overview on Measurement Method for Secondary Circuit Disconnection in High Voltage Circuit Breaker
下载PDF
导出
摘要 高压断路器是电力系统中的主要设备,二次回路发生故障时,将影响断路器正常操作,威胁系统安全运行。介绍了高压断路器操动机构二次回路断路时,采用通断法、测电压降法和对地电位法对二次回路进行测量和检验,通过综合应用分析,迅速准确做出判断,排除故障。 High voltage circuit breaker is the major equipment of power system. Secondary circuit disconnection may influence directly opening and closing operation of the breaker, and threaten the secure and stable operation of the power system. The paper introduces the measurement method for the electric quantity when secondary circuit disconnects in the operating mechanism of the high voltage circuit breaker and its application, based on which the fauhs can be eliminated quickly and accurately..
作者 陈琦
机构地区 渭南供电局
出处 《陕西电力》 2012年第12期68-71,共4页 Shanxi Electric Power
关键词 断路 二次回路 测量方法 应用分析 disconnection secondary circuit measurement method application analysis
  • 相关文献

参考文献1

  • 1文锋.电气二次接线知识[M]北京:中国电力出版社,2005. 被引量:1

同被引文献111

引证文献9

二级引证文献93