摘要
成都地区地下水位高,抗浮问题是地下空间结构设计中需要解决的最主要问题之一。目前尚没有一个国家规范或地方规范对抗浮锚杆设计进行系统、详细的规定。本文根据设计和施工的实践,结合某工点抗浮锚杆的极限抗拔静载荷试验,对抗浮锚杆设计方法进行梳理和探讨。
Anit-floating is a main problem in underground space design in Chenddu City. However, there is no technical code for anti- float anchor design today. This paper aims to establish an design method for anti-float anchor through analysis behavior of anti-float anchor with basic tests and author's design and construction practice.
出处
《四川建筑科学研究》
2012年第6期131-134,共4页
Sichuan Building Science