摘要 在分析影响现有辐照后板材厚度测量不确定度高的原因基础上,进行了大量的对比测量试验,得到了相关测量数据,提出了一系列改进措施,对原有热室内辐照后板材厚度测量方法进行了改进。通过设计专用测量夹具,将原有机械手拖动测量方式改为夹具导向式测量,有效地解决了板材厚度测量时竖直侧立问题,标准试块固定问题及电感测微仪测头与板材接触力问题,使测量数据不确定度降低了1个数量级,大大降低了人员接受剂量、劳动强度及设备使用时间,取得了明显的经济效益和社会效益,填补了国内辐照后板材厚度精确测量在核能研究与应用领域的空白,所改进的测试方法有很好的应用前景。 The high uncertainty in the thickness measurement of post irradiation sheet was analyzed, and based on the analysis, a large number of measurement tests were taken, a series of improvements were proposed. The manipulator driving measurement was replaced with the action-oriented measurement, which has effectively solved the problems concerning the stick side determination, the standard block fixing and the control of the head contact forces. The measurement uncertainty was reduced by one order of magnitude. The radiation dose, the labor tension and the time were likewise reduced with very significant economic and social benefits.
出处 《科技导报》 CAS CSCD 北大核心 2012年第34期61-64,共4页 Science & Technology Review
关键词 辐照后板材 厚度测量 不确定度 post irradiation sheet thickness measurement uncertainty