摘要 基于短路阻抗法原理研究了对绕组变形的在线监测技术和实验室研究平台。提出了一种快速计算变压器绕组漏电抗的计算方法:在电流峰值处,直接由电压差和电流比值得到漏电阻;在电流过零处,直接由电压差和电流微分的比值得到漏电感;对一、二次电压先在硬件电路中先进行减法放大到采集卡的输入极值附近,再采集,将算法的分辨率几近提高到采集卡的最大精度。研制的监测系统,在实验室绕组变形研究平台上进行试验研究并初步提出变形判据,并在现场得到应用。研究结果表明,这为现场变压器在线监测绕组故障提供了一种有效的方法。 An on-line monitoring technology of transformer winding deformation and corresponding experimental platform were presented according to the theory of short-circuit impedance analysis. Consequently, a method for rapidly computing the leakage reactance from transformer winding was proposed. The leakage resistance is obtained from the ratio of voltage difference to current at the peak of current, and the leakage inductance is also obtained from the ratio of voltage difference to differential of current when current is zero. The voltage difference of primary and secondary winding is magnified near the input limit of AD acquisition card with hardware before sampled, thus the resolution of the algorithm is increased to the maximum precision of the card. The present on-line monitoring system was tested on the experimental platform, and a criterion was also proposed for judging the state of winding. The test and practical application results verify the effectiveness of the present on-line monitoring system.
出处 《高压电器》 CAS CSCD 北大核心 2012年第12期44-48,共5页 High Voltage Apparatus
关键词 绕组变形 在线监测 短路阻抗法 漏电抗 winding deformation on-line monitoring short-circuit reactance analysis leakage reactance
  • 相关文献

参考文献19

二级参考文献26

  • 1姚森敬,欧阳旭东,林春耀.电力变压器绕组变形诊断分析[J].电力系统自动化,2005,29(18):95-98. 被引量:43
  • 2王钰,李彦明,张成良.变压器绕组变形检测的LVI法和FRA法的比较研究[J].高电压技术,1997,23(1):13-15. 被引量:57
  • 3Humbard L E,Gillies D A.Instrumentation techniques for low voltage impulse testing of power transformers[J].IEEE Trans on PAS,1972,91(3):1281-1293 被引量:1
  • 4Lech W,Tyminski L.Detecting transformer winding damage The low voltage impulse method[J].Electrical Review,1966,176 (21):768-772. 被引量:1
  • 5Leibfried T,Feser.Monitoring of power transformers using the transfer function method[J].IEEE Trans on PD,1999,14(10):1333-1341. 被引量:1
  • 6Bengtsson.Status and trends in transformer monitoring[J].IEEE Trans on Power Delivery,1996,11(3):1379-1348. 被引量:1
  • 7Arri E,Mocci F,Tosi M.On-line monitoring of electrodynamic effects on power transformers windings[C].Proc IEEE Instrum Meas.Technol Conf:IMTC '92 NY,1992:466-469. 被引量:1
  • 8Arri E,Carta A,Mocci F,et al.Diagnosis of the state of power transformer windings via on-line measurement of stray reactance[C].Proc CPEM '92 Cont.Paris,1992:338-339.and IEEE Trans on Instrum Meas Special Issue,1993,42(2):312-378. 被引量:1
  • 9DING F, CHEN T. Identification of multivariable systems based on finite impulse response models with flexible orders[C]//Proceeding of the IEEE International Conference on Mechatronics & Automation Niagara Falls. Piscataway: IEEE, 2005 : 770-775. 被引量:1
  • 10SACHDEV M S, SIDHU T S, WOOD H C. A digital relaying algorithm for detecting transformer winding faults[J]. IEEE Trans on Power Delivery, 1989, 4 (3): 1638-1648. 被引量:1

共引文献221

同被引文献108

引证文献7

二级引证文献108

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部