期刊文献+

浅析网络协议在机房电源末端解决方案中的应用 被引量:1

Application of Network Protocols at the End of the Power Supply Solutions of Computer Room
下载PDF
导出
摘要 为了适应大型机房的自动化控制、智能管理的需要,机房中的众多子系统如空调系统、配电系统、环境监控系统等均采用了智能化的监控平台,而机房中的电源末端监控系统的管理刚刚起步。文中提出了一种兼容于工业系统的电源末端管理方式,讨论了TCP/IP协议及Modbus协议在机房电源管理系统中的应用,阐述了该系统设计的思想和方法,并已通过测试证实其可行性和稳定性。该系统采用分层架构,各层采用不同的通讯协议,具有灵活性、兼容性强、实时性、稳定性、安全性等特点。 In order to adapt to the needs of the large computer room automation control, intelligent management, many subsystems in the rooms such as the air conditioning system, distributed power systems, environmental monitoring system, etc, all use intelligent monitoring platform. But the management of power supply terminal monitoring system in computer has just started. In this article proposed one power supply terminal management mode compatible with industrial system, discussed TCP/IP protocol and Modbus protocol in the application of computer room management system, elaborated on the ideas and methods of the system design, has been tested to prove its viability and stability. This system has a layered structure, each layer uses different communication protocols with flexibility, compatibility, and real- time, stability, secu rity, etc.
作者 张皆喜
出处 《通信电源技术》 2012年第6期65-66,98,共3页 Telecom Power Technology
关键词 数据通讯 TCP IP协议 MODBUS协议 智能PDU data communication TCP/IP protocol Modbus protocol intelligent PDU
  • 相关文献

参考文献6

  • 1雷思孝主编..计算机数据通信[M].西安:西安电子科技大学出版社,2006:270.
  • 2王晓燕,冯江主编..自动控制理论实验与仿真[M].广州:华南理工大学出版社,2006:172.
  • 3范逸之等编著..利用Visual Basic实现串并行通信技术[M].北京:清华大学出版社,2001:544.
  • 4蓝玉龙.TCP/IP协议及其工作原理[M].北京:电子工业出版社,2000. 被引量:1
  • 5李元臣,刘维群.基于TCP/ IP协议的点对点通信[M].北京:机械工业出版社,2002. 被引量:1
  • 6李元熙.基于TCP/IP的计算机通讯系统实现[M].北京:清华大学出版社,2004. 被引量:1

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部