期刊文献+

XE-2100散点图分析用于白血病FAB分型的初筛的研究

Study on the Primary Screening Method of Leukemia Fab Types by the Scatter Graph of Sysmex XE-2100
下载PDF
导出
摘要 目的通过对1,582例临床确诊的白血病患者外周全血标本的检测,研究Sysmex XE-2100散点图的分布趋势,建立一套用于白血病FAB分型系统初筛的方法,从而减少临床初诊时对相关血液系统疾病的误诊与漏诊。方法利用Sysmex XE-2100全血细胞分析仪检测外周全血标本,并对XE-2100系统中DIFF通道、BASO通道以及IMI通道三部分的散点图进行综合评估。结果DIFF通道与IMI通道可以将粒系统白血病与淋巴系统和单核系统白血病进行区分,识别率分别为94.8%、96.8%、81.3%;对L1型、L2型、L3型的识别率分别为30.6%、34.8%、33.5%;对M1型、M2型、M3型、M4型、M5型、M6型、M7型的识别率为62.9%、44.5%、44.8%、47.0%、40.3%、30.9%、0%。结论XE-2100散点图可以用于粒系统、单核系统及淋巴系统白血病的初步鉴别,可以对M1、M2、M3进行初步鉴别,但无法对单核系统M4与M5、及淋巴系统白血病进行鉴定,其他系统及类型的白血病无法应用。 Objective To determine the whole blood specimen in 1,582 cases leukemia patients with confirmed diagnosis,study the distribution and tendency of scatter graph of Sysmex XE-2100 analyzer, and establish a primary screening method for leukemia FAB typing,thereby to reduce the misdiagnosis of the blood system diseases when first visited.Methods We determined the specimens with Sysmex XE-2100 analyzer, evaluated the scatter graph of DIFF, BASO,and IMI channel in XE-2100 system.Results We can differentiate the granulocyte leukemia from monocytic leukemia and the lymphocytic leukemia in the DIFF and IMI channels,the identification ratio are 94.8%,96.8% and 81.3%;the identification ratio to L1,L2 and L3 are 30.6%,34.8%,33.5%;the identification ratio to M1,M2,M3,M4,M5,M6 and M7 are 62.9%,44.5%,44.8%,47.0%, 40.3%,30.9%,0%.Conclusion We can differentiate the granulocyte leukemia from monocytic leukemia and the lymphocytic leukemia,and can differentiate M1,M2 and M3,but can not differentiate all types of lymphocytic leukemia,and can not differentiate M4 from M5.
作者 郑军
出处 《中国血液流变学杂志》 CAS 2012年第3期518-521,548,共5页 Chinese Journal of Hemorheology
关键词 XE-2100 FAB分型 XE-2100 FAB typing
  • 相关文献

参考文献5

二级参考文献12

  • 1朱晓辉,马洪玉,朱忠勇.应用血液学分析仪后显微镜复检标准刍议[J].中国实验诊断学,2006,10(3):296-298. 被引量:18
  • 2王小林,王宇,吴永华.XE-2100全自动血液分析仪自动幼稚粒细胞计数与显微镜方法比较[J].现代检验医学杂志,2006,21(6):62-63. 被引量:10
  • 3Fernandes B, Hamaguchi Y. Automated Enumeration of Immature Granulocytes[J]. Am J Clin Pathol, 2007,128(3):454-463. 被引量:1
  • 4Fujimoto H, Sakata T, Hamaguchi Y, et al. Flow cytometric method for enumeration and classification of reactive immature granulocyte populations[J]. Cytometry. 2000,42(6):371-378. 被引量:1
  • 5Ansari-Lori MA, Kidder TS, Borowitz MJ. Immature granulocyte measurement using the Sysmex XE-2100: relationship to infection and sepsis[J]. Am J Clin Pathol, 2003,120(5):795-799. 被引量:1
  • 6Nigro KG, O'Riordan M, Molloy E J, et al. Performance of an automated immature granulocyte count as a predictor of neonatal sepsis [J]. Am J Clin Pathol, 2005323(4):618-624. 被引量:1
  • 7Barnes PW, Mcfadden SL, Machin SJ, et al. The International Consensus Group for Hematology Review: suggested criteria for action following automated CBC and WBC differential analysis [J]. Lab Hematol, 2005,11(2):83-90. 被引量:1
  • 8Ansari-Lari MA,Kickler TS,Borowitz MJ.Immature granulocyte measurement using the Sysmex XE-2100.Relationship to infection and sepsis[J].Am J Clin Pathol,2003,120(5):795-799. 被引量:1
  • 9Field D,Taube E,Heumann S.Performance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer[J].Lab Hematol,2006,12(1):11-14. 被引量:1
  • 10Fernandes B,Hamaguchi Y.Automated enumeration of immature granulocytes[J].Am J Clin Pathol,2007,128(3):454-463. 被引量:1

共引文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部