摘要 超滤膜在城市净水工艺中的应用,选择合适的阈通量是其成功的关键之一。围绕这一关键点,使用4种膜材料(PVC、PVDF、PES和PS)过滤原水,比较分析不同膜材料对阈通量的影响。结果表明PVDF膜的抗污染性最高,所求不可逆阈通量大于30L/(m2.h)。PS膜由于相对较小的截留分子质量,导致污染最严重,不可逆阈通量最小。PVC和PES膜对污染比较敏感,可以测定多个阈通量。 As for the application of ultrafiltration in municipal water treatment process,one of the key points was the selection of suitable threshold flux.Based on this opinion,four different membranes(PVC,PVDF,PES and PS) were applied to raw water filtration.The effects of different membranes on threshold flux were compared and analyzed.The irreversible threshold flux of PVDF was more than 30 L/(m2·h),which verified its highest anti-fouling ability among these materials.The irreversible threshold flux of PS was lowest due to low molecular weight cutoff.PVC and PES could display several threshold fluxes due to their sensitivity to fouling.
出处 《给水排水》 CSCD 北大核心 2012年第11期127-131,共5页 Water & Wastewater Engineering
基金 国家自然科学基金重点资助项目(51138008) 粤港关键领域重点突破项目(2010Z52401)
关键词 超滤膜 阈通量 膜材料 污染速率 Ultrafiltration membrane Threshold flux Membrane material Fouling rate
  • 相关文献

参考文献5

  • 1Field R W, Wu D, Howell J A, et al. Critical flux concept for microfiltration fouling. Journal of Membrane Science, 1995, 100 (3): 259-272. 被引量:1
  • 2李圭白,梁恒.超滤膜的零污染通量及其在城市水处理工艺中的应用[J].中国给水排水,2012,28(10):5-7. 被引量:17
  • 3Field R W,Pearce G K. Critical, sustainable and threshold fluxes for membrane filtration with water industry applications. Advances in Colloid and Interface Science,2011,164:38-44. 被引量:1
  • 4Bacchin P, Aimar P , Field R W. Critical and sustainable fluxes: Theory, experiments and applications. Journal of Membrane Science, 2006, 281:42-69. 被引量:1
  • 5van der Marel P, Zwijnenburg A, Kemperman A, et al. An improved flux- step method to determine the critical flux and the critical flux for irreversibility in a membrane bioreactor. Journal of Membrane Science, 2009, (332) .. 24-29. 被引量:1

二级参考文献4

  • 1Field R W, Pearce G K. Critical, sustainable and threshold fluxes for membrane filtration with water industry applications[ J]. Adv Colloid Interface Sci, 2011,164 (1/ 2) :38 -44. 被引量:1
  • 2Bacchin P, Aimar P, Field R W. Critical and sustainable fluxes :theory, experiments and applications [ J ]. J Mere Sci ,2006,281 ( 1/2 ) :42 - 69. 被引量:1
  • 3Clech P L, Jefferson B, Chang I S,et al. Critical flux determination by the flux-step method in a submerged membrane bioreactor[ J ]. J Membr Sci, 2003,227 (1/2) : 81 -93. 被引量:1
  • 4李圭白,田家宇,齐鲁.第三代城市饮用水净化工艺及超滤的零污染通量[J].给水排水,2010,36(8):11-15. 被引量:64