期刊文献+

制氟用炭阳极石墨化度的确定及其检测标准 被引量:2

THE DETERMINATION OF GRAPHITIZATION DEGREE AND ITS TESTING STANDARD OF CARBON ANODE FOR FLOURINE PRODUCTION
下载PDF
导出
摘要 采用正交偏光加石膏检板的显微镜光学干涉分析法测定制氟阳极误混入的石墨碎(粉)含量。结果表明 :试样的可检测面积为15~20cm2 ,≤0.15mm石墨碎颗粒控制在10处以内 ,<0.4mm石墨碎颗粒控制在5处以内。 The way that the content of graphite crushing (powder or dust) mixed during feed proportion was determined by interferance, which was adopted orthogonal and polarizing light through optical microscope was founded, and testing gypsum plate was required. The result shows that the testing area of the sample is in 15~20 cm2. The graphite crushing particals which were lower than 0.15 mm was controlled 10 parts, and ones lower than 0.4 mm were controlled 5 parts.
作者 解胜利
出处 《炭素技术》 CAS CSCD 2000年第2期42-43,共2页 Carbon Techniques
关键词 制氟 炭阳极 石墨化度 检测标准 电解槽 电极 Carbon anode for fluorine production graphitization degree testing