摘要 The application of a high purity Germanium (HPGe) γ spectrometer in determining the fuel element burnup in a future reactor is studied. The HPGe detector is exposed by a 60Co source with varying irradiation rate from 10× 103m s-1 to 150× 103m s-1 to simulate the input counting rate in real reactor environment. A 137Cs and a 152Eu source are positioned at given distances to generate a certain event rate in the detector with the former being proposed as a labeling nuclide to measure the burnup of a fuel element. It is shown that both the energy resolution slightly increasing with the irradiation rate and the passthrough rate at high irradiation level match the requirement of the real application. The influence of the background is studied in the different parameter sets used in the specially developed procedure of background subtraction. It is demonstrated that with the typical input irradiation rate and 137Cs intensity relevant to a deep burnup situation, the precision of the 137Cs counting rate in the current experiment is consistently below 2.8%, indicating a promising feasibility of utilizing an HPGe detector in the burnup measurement in future bed-like reactors. The application of a high purity Germanium (HPGe) γ spectrometer in determining the fuel element burnup in a future reactor is studied. The HPGe detector is exposed by a 60Co source with varying irradiation rate from 10× 103m s-1 to 150× 103m s-1 to simulate the input counting rate in real reactor environment. A 137Cs and a 152Eu source are positioned at given distances to generate a certain event rate in the detector with the former being proposed as a labeling nuclide to measure the burnup of a fuel element. It is shown that both the energy resolution slightly increasing with the irradiation rate and the passthrough rate at high irradiation level match the requirement of the real application. The influence of the background is studied in the different parameter sets used in the specially developed procedure of background subtraction. It is demonstrated that with the typical input irradiation rate and 137Cs intensity relevant to a deep burnup situation, the precision of the 137Cs counting rate in the current experiment is consistently below 2.8%, indicating a promising feasibility of utilizing an HPGe detector in the burnup measurement in future bed-like reactors.
出处 《Chinese Physics C》 SCIE CAS CSCD 2012年第11期1082-1088,共7页 中国物理C(英文版)
基金 Supported by National Science and Technology Major Project(ZX06901) National Natural Science Foundation of China (10975083) Tsinghua University Initiative Scientific Research Program
关键词 fuel element burnup γ ctivity HPGE γ pectrometer fuel element burnup, γ ctivity, HPGe, γ pectrometer
  • 相关文献

参考文献14

  • 1Hawari A I, CHEN J. IEEE Transactions on Nuclear Sci ence, V, 2002, 49(3): 1249. 被引量:1
  • 2SU B, ZHAO Z, CHEN J, Ayman I. Hawari, Prog. Nucl. Ener., 2006, 48:686. 被引量:1
  • 3Matsson I. SKI Report, 1995, 95:46. 被引量:1
  • 4Matsson I, Grapengiessen B. Appl. Radiat. Isot., 1997, 48(10-12): 1289 1298. 被引量:1
  • 5Terremoto L A A, Zeituni C A et al. Nucl. Instrum. Meth- ods A, 2000, 450:495. 被引量:1
  • 6Ansari S A, Asif M et al. Annals of Nuclear Energy, 2007, 34:641. 被引量:1
  • 7Willman C, Hakansson A et al. Annals of Nuclear Energy, 2006. 33:427. 被引量:1
  • 8Khan R, Karimzadeh S, BSck H. Nuclear Engineering and Design, 2010, 240:1043. 被引量:1
  • 9Matsurra S, Tsuruta H et al. Ncul. Sci. Tech., 1975, 12:24. 被引量:1
  • 10ZHANG L G, LIT S et al. Nuclear Power Engineering, 2008, 29:018 (in Chinese). 被引量:1

同被引文献20

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部