摘要
结合工程实例分析发电机组的负荷计算,对柴油发电机容量的选择进行探讨,分别计算消防负荷与保障性负荷,按其中较大负荷值来确定发电机容量。
In combination with actual engineering projects, load calculation of generating set is analyzed and choice of capacity of diesel generating set is discussed. Fire load and indemnifieatory load is calculated respectively, and the larger load value is used to determine the generator capacity.
出处
《建筑电气》
2012年第9期30-33,共4页
Building Electricity
关键词
高层建筑
应急电源
备用电源
柴油发电机组
消防负荷
保障性负荷
High-rise building Electric sourcefor safety servies Stand-by electric source Dieselgenerating set Fire load Indemnificatory load