期刊文献+

湖南电网严重冰灾天气成因分析 被引量:2

Preliminary Study on the Weather Forecast Index of Ice Damage Impact on Power Grid in Hunan
下载PDF
导出
摘要 为研究2005年初和2008年初2次造成湖南电网严重冰灾的低温雨雪冰冻天气过程的成因,利用NCEP1°×1°全球再分析资料、地面常规气象观测资料及环流特征指数资料对过程期间高中低三层的水平和垂直结构进行了诊断分析,并分析了两次冰冻天气过程中各项环流特征指数与气温的相关性,结果表明:副高强度持续偏强,中层有暖层存在,850hPa与700hPa有明显的逆温层,700hPa强劲的西南急流,850hPa南北温差锋区的建立和维持,异常强大的冷高压长时间控制是造成两次冰灾过程的主要原因;地面降水、相对湿度、日平均气温、日最低气温、风向风速均与电线覆冰直径有关,温度垂直结构、环流指数和地形也与冰冻有一定关系。 Two extremely ice disaster events attacked Hunan power grid in early 2005 and early 2008. In order to study cause of the two ice disaster processes, the horizontal and vertical structure of the high, medium and low level, the correlation between circulation characteristic index and temperature during two freezing weather processes were analyzed with the usage of the NCEP 1 °× 1° global analysis data, conventional observation data and circulation features index data, and it is found that, two ice disaster events were directly caused by continuous strong subtropical high strength, the existence of the middle-level warm layer, obvious inversion layer at 850hPa and 700hPa, south- western jet flow at 700hPa, the formation and duration of north-and-south temperature front zone and longtime strong cold anticyclone. In the meantime, the research also discovered the precipitation, relative humidity, the average daily temperature, the minimum daily temperature, wind direction, wind speed, the temperature vertical structure, circulation index and terrains had some relation to the frozen weather.
出处 《成都信息工程学院学报》 2012年第4期419-428,共10页 Journal of Chengdu University of Information Technology
基金 2011年度中国气象局城市气象防灾减灾专项电力气象服务试点资助项目(1411120090003)
关键词 天气学 冰冻成因分析 环流形势 影响因子 电网 synoptic meteorology analysis of freezing causes circulation situation impact factors power grid
  • 相关文献

参考文献15

二级参考文献76

共引文献933

同被引文献40

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部