摘要
X/γ探测器在航天等国家战略需求领域具有非常广泛和重要的应用。然而,X/γ探测器要在其有效能区进行精确的标定后才能发挥作用。目前我国缺乏sub-MeV~MeV能量连续可调、单色性好的γ源,而用于航天的X/γ探测器无法完成精确定标,从而使航天探测的发展出现瓶颈问题。提出了升级原有的激光康普顿散射(LCS)原理性实验装置的方案,建立了一个通过改变激光入射角来连续调节散射光子能量、准单色、极化、sub-MeV~MeV LCS光源(SINAP-III),从而开拓LCS光源在我国航天领域(如用于航天的X/γ探测器能量定标和抗辐射加固评估研究)的崭新应用前景,并为将来建设一个基础和应用研究相结合的多功能的γ源实验平台打下基础。
The X/7 detectors in the field of national stratagem, such as astronautical technology, have very broad and important application. These detectors, however, will play their role properly only after accu- rate calibrations in effective energy region. For the shortage of continuously adjustable and quasi-mono- chromatic )' source in China, it is impossible for the detector employed in aerospace to achieve an accurate calibration so that development of such detector has encountered a big obstacle (or a bottleneck). There- fore, we propose to upgrade the original LCS device to an adjustable photon energy by changing incident angle of laser beam, monochromatic, and polarized sub-MeV-MeV LCS 7 source(SIMAP-III) , in order to explore the new applications of LCS 7 source in aerospace as well as to establish a platform for a multi- functional of 7 source.
出处
《原子核物理评论》
CAS
CSCD
北大核心
2012年第3期253-258,共6页
Nuclear Physics Review
基金
国家自然科学基金重点项目(2610701)~~
关键词
LCS光源
能量可调
航天用探测器定标
可旋转靶室
LCS y source adjustable energy detector calibration for aerospace rotatable target chamber