期刊文献+

大型风电场次同步谐振分析 被引量:11

Sub-synchronous Resonance of Large-Scale Wind Farm
原文传递
导出
摘要 含恒速异步风力发电机的大型风电场通过含串补线路外送功率时存在次同步谐振问题。以PSCAD/EMTDC仿真软件为工具,建立了适用于风电场次同步谐振分析的大型风电场仿真模型,并在多种运行方式下分析了该风电场通过一串补线路外送功率时的次同步谐振特性和机组扭振特性。另外,还分析了大型风电场与火电厂捆绑送电方式下系统次同步谐振特性。 Sub-synchronous resonance may occur when power is transmitted through series compensated lines from large-scale wind farm with constant-speed asynchronous wind turbines. This paper adopted PSCAD/EMTDC simula- tion software and established simulation model for the analysis of sub-synchronous resonance in large-scale wind farm. Thereby, research was conducted on the characteristics of sub-synchronous resonance and torsional vibration when power was transmitted in various operation modes through a series compensated line from a large-scale wind farm. In addition, the characteristics of sub-synchronous resonance were analyzed when the power from large-scale wind farm and thermal power plant were bundled together in power transmission.
出处 《华东电力》 北大核心 2012年第8期1328-1333,共6页 East China Electric Power
基金 国家自然科学基金项目(51037003)~~
关键词 大型风电场 次同步谐振 捆绑送电 PSCAD/EMTDC large-scale wind farm sub-synchronous resonance bundled power transmission PSCAD/EMTDC
  • 相关文献

参考文献14

  • 1汪宁渤.甘肃酒泉千万千瓦风电基地面临的挑战及应对措施[J].电网与清洁能源,2009,25(7):43-47. 被引量:42
  • 2雷亚洲.与风电并网相关的研究课题[J].电力系统自动化,2003,27(8):84-89. 被引量:457
  • 3POURBEIK P, KOESSI,ER R J, D1CKMANDER D L, et al. Integration of Large Wind Farms into Utility Grids ( Pro1 2 - Performance Issues) [ C ]. IEEE Power Engineering Society General Meeting Conf,2003. 被引量:1
  • 4VARMA R K,AUDDY S. Mitigation of subsynchronous oseil-lations in a series compensated wind farm with static var com- pensator[ C ]. Proceedings of IEEE Power Engineering Socie- ty Gener~ Meeting,2006. 被引量:1
  • 5VARMA R K, SEMSEDINI Y, AUDDY S. Mitigation of sub- synchronous oscillations in a series compensated wind farm with thyristor controlled series capacitor (TCSC) [ C ]. Pro- ceedings of IEEE Power Systems Conference:Advanced Mete- ring, Protection, Control, Commanication, and Distributed Re- soarees,2007. 被引量:1
  • 6VARMA R K, AUDDY S, SEMSEDINI Y. Mitigation of sub- synchronous resonance in a series-compensated wind farm u- sing FACTS controllers[J]. IEEE Trans on Power Delivery, 2008,23(3) :1645-1654. 被引量:1
  • 7EL-MOURSI M S,BAK-,1ENSEN B,ABDEL-RAHMAN M H. Novel STATCOM controller fi)r nritigating SSR and damping power system oscillations in a seri~ c,ompenm~ted wind parks [ J ]. IEEE Trans on Power Eleetnmics,2010,25 (2) :429-441. 被引量:1
  • 8ZHU Chan-xia,FAN Ling-ling,HU Min-qiang. Modeling and simulation of a DFlG-based wind turbine for SSR[ C]. North American Power Symposium ( NAPS), Starkville, MS, USA, 2009. 被引量:1
  • 9顾威,李兴源,王渝红,穆子龙,魏巍.UPFC对风电场次同步谐振的抑制作用[J].电力系统自动化,2010,34(8):101-105. 被引量:29
  • 10MUYEEN S M,ALI M H,TAKAHASHI R, et al. Blade-shaft torsional oscillation minimization of wind turbine generator system by using STATCOM/ESS [ C ]. Power Tech, 2007 IEEE Lausanne,Switzerland, 2007. 被引量:1

二级参考文献62

  • 1杨帆,王西田,徐英新,陈陈.同型多机电力系统间扭振相互作用的等效简化研究[J].中国电机工程学报,2006,26(5):6-11. 被引量:22
  • 2李炜,佟明东,张琳,徐东杰,林峰,李新,左郑敏.“十一五”南方电网“西电东送”输电能力研究[J].中国电力,2007,40(2):26-30. 被引量:11
  • 3KUMAR R, HARADA A, MERKLE M, et al. Investigation of the influence of series compensation in AC transmission systems on bus connected parallel generating units with respect to subsynchronous resonance (SSR)// Proceedings of the 2003 IEEE Power Tech Conference: Vol 3, June 23-26, 2003, Bologna, Italy: 23-26. 被引量:1
  • 4KUMAR R, HARADA A, MERKLE M, et al. A new approach for determining series compensation ratio for transmission systems with bus connected parallel generating units considering subsynchronous resonance as a constraint// Proceedings of CIGRE/IEEE PES International Symposium on Quality and Security of Electric Power Delivery Systems, October 8-10, 2003, Montreal, Canada: 22-27. 被引量:1
  • 5MOLINAS M, ARE SUUL J, UNDELAND T. Torque transient alleviation in fixed speed wind generators by indirect torque control with STATCOM// Proceedings of the 13th Power Electronics and Motion Control Conference, September 1-3, 2008, Poznan, Poland: 2318-2324. 被引量:1
  • 6VARMA R K, AUDDY S, SEMSEDINI Y. Mitigation of subsynchronous resonance in a series-compensated wind farm using FACTS controllers. IEEE Trans on Power Delivery, 2008, 23(3): 1645-1654. 被引量:1
  • 7VARMA R K, SEMSEDINI Y, AUDDY S. Mitigation of subsynchronous oscillations in a series compensated wind farm with thyristor controlled series capacitor (TCSC)// Proceedings of IEEE Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources, March 13-16, 2007, Clemson, SC, USA: 331-337. 被引量:1
  • 8VARMA R K, AUDDY S. Mitigation of subsynchronous oscillations in a series compensated wind farm with static var compensator// Proceedings of IEEE Power Engineering Society General Meeting, June 18-22, 2006, Montr4al, Canada: 7p. 被引量:1
  • 9EL-MOURSI M S, BAK-JENSEN B, ABDEL-RAHMAN M H. Novel STATCOM controller for mitigating SSR and damping power system oscillations in a series compensated wind parks. IEEE Trans on Power Electronics, 2010, 25 (2): 429-441. 被引量:1
  • 10POURBEIK P, KOESSLER R J, DICKMANDER D L, et al. Integration of large wind farms into utility grids: Part 2 perfqrmance issues// Proceedings of IEEE Power Engineering Society General Meeting: Vol 3, July 13 17, 2003, Toronto, Canada: 1520-1525. 被引量:1

共引文献523

同被引文献161

引证文献11

二级引证文献267

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部