摘要 陕京三线输气管道工程对受交流干扰的区段采用了集中接地、故障屏蔽、固态去耦合器接地等交流干扰防护新技术,通过现场干扰程度调查与测试、防护效果检测评价、固态去耦合器运行参数、持续干扰防护接地点优化调整与测试等工作,获得了详细的实际数据,对固态去耦合器接地方式新技术的应用情况,以及防护点的优化等进行了总结,为埋地钢管交流干扰防护工程的设计、施工及运行测试提供参考。 New technologies such as lumped ground , fault shield and solid-state DC; decoupler grounding were used to protections against AC influence in Shanxi-Beijing Gas Pipeline Ⅲ. The application of solid-state DC decoupler grounding and the optimization of protection point were summarized. Based on the detailed data from the on-site tests of influence degree, inspections of protection effects, analyses of operation parameters of solid-state DC decoupler and optimization of grounding point the solid-state DC; decoupler technology were summarized, which may provide a reference to the design, construction, operation and inspection of protection against AC influence for underground steel pipelines.
出处 《腐蚀与防护》 CAS 北大核心 2012年第8期724-727,共4页 Corrosion & Protection
关键词 固态去耦合器 交流干扰防护 效果评定 交流腐蚀 接地 solid-state DC decoupler AC influence mitigation assessment AC corrosion grounding
  • 相关文献

参考文献4

  • 1AS/NZS4853:2000澳大利亚/新西兰标准《金属管道上的电危害》[S]. 被引量:2
  • 2NACESP0177-2007.减轻交流电和雷电对金属构筑物和腐蚀控制系统影响的措施[S]. 被引量:2
  • 3Dabkowski J. Methodlogies for AC mitigation [C]// Corrosion 2003, Paper No. 03703, Houston TX: NACE Int, 2003. 被引量:1
  • 4ISO15589-1:2003.管道输送系统的阴极保护(第一部分:陆上管道)[S]. 被引量:1

共引文献2

同被引文献46

  • 1李绍忠.地下金属管道交流干扰的防护[J].腐蚀科学与防护技术,1989,1(2):24-29. 被引量:2
  • 2郭庆茹,何悟忠,左戈,董仲智,陈敬和,李增平,冷旭跃,李振华.电气化铁路对输油管道的干扰及其防护方法的研究[J].石油工程建设,2005,31(4):51-54. 被引量:13
  • 3GB/T50698-2011埋地钢质管道交流干扰防护技术标准[S]. 被引量:12
  • 4Robert G. Wakelin, Christopher Sheldon. Investigation and mitigation of AC corrosion on A 300 mm diameter natural gas pipeline [C]~//New Orleans.. Louisiana Cor- rosion 2004, Paper No. 04205. 被引量:1
  • 5GB/T506982011.埋地钢质管道交流干扰防护技术标准[S]. 被引量:2
  • 6DD CEN / TS 15280 : 2006 BSi. Evaluation of a. c. cor- rosion likelihood of buried pipelines - application to cathodically protected pipelines[S]. 被引量:1
  • 7R.W. Bosch,W.F. Bogaerts.A theoretical study of AC-induced corrosion considering diffusion phenomena[J].Corrosion Science.1998(2) 被引量:1
  • 8NACE SP0177-2014 Mitigation of alternating cur- rent and lightning effects on metallic structures and corrosion control systemsFS:. 被引量:1
  • 9DD CEN/TS 15280-2006 Evaluation of a. c. corro- sion likelihood of buried pipelines-application to ca- thodically protected pipelines[-S:. 被引量:1
  • 10SY-T0032-2000埋地钢质管道交流排流保护技术规范[s]. 被引量:1

引证文献7

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部