一种外科手术器械——钳钩施夹器 被引量:1

A Surgical Instrument — Endoscopic Clip Applier with a Hook
下载PDF
导出
摘要 介绍了一种外科手术钳钩施夹器。它是在传统施夹器的基础上,加装钳钩装置、先收拢后夹闭装置和收钳钩装置而成。主要应用于人体腔镜和体外手术中。其优点是能增加结扎宽度,无需重复上夹,方便单视野下操作,节省手术时间。 A endoscopic clip applier with a hook is introuduced. It combines a hook appliance on the traditional clip applicator, and it is mainly used in endoscopic surgery. It can increase the width of ligation, without repeatly clamping, It is easy to use in single view operations, save operating time.
出处 《中国医疗器械杂志》 CAS 2012年第4期308-309,共2页 Chinese Journal of Medical Instrumentation
关键词 外科 器械 施夹器 钛夹钳 钳钩 surgical, instrument, endoscopic clip applier, clip applicator, hook
  • 相关文献

参考文献3

二级参考文献12

共引文献16

同被引文献13

  • 1陈文莉,李青峰,雷华,朱昌,张波,余力,王健.不同类型乳房假体隆乳术后并发症的临床分析[J].中华整形外科杂志,2005,21(3):172-174. 被引量:36
  • 2Jacobson JM1, Gatti ME, Schaffner AD, et al. Effect of incision choice on outcomes in primary breast augmentation [ J ]. Aesthet Surg J, 2012,32(4) :456-462. 被引量:1
  • 3国务院令第276号.医疗器械监督管理条例[S].北京:国务院,2000:1. 被引量:1
  • 4Aygit AC, Basaran K, Mercan ES. Transaxillary totally subfascial breast augmentation with anatomical breast implants: review of 27 cases [ J]. Hast Reconstr Surg, 2013,1 3 1( 5 ) : 1149 -1 1 56. 被引量:1
  • 5Steiert AE, Boyee M, Sorg H. Capsular eontracture by silicone breast implants: possible causes, biocompatibility, and prophylac- tic strategies [ J ]. Med Devices ( Auckl), 2013,6 (2) :211-218. 被引量:1
  • 6Stevens WG, Nahabedian MY, Calobrace MB, et al. Risk factor analysis for capsular contracture : a 5-year Sientra study analysis u- sing round, smooth, and textured implants for breast augmentati on[J]. Plast Reconstr Surg, 2013,132(5) :1115-1123. 被引量:1
  • 7Gruber RP, Friedman GD. Periareolar subpectoral augmentation mammaplasty [ J ]. Plast Reconstr Surg, 1981,67 ( 4) :453-457. 被引量:1
  • 8Lee W, Choi BK, Bang SI, et al. Augmentation Mammoplasty With Silicone Implant Using Transumbilical Approach at a Subpec- total Level[ J]. Ann Plast Surg, 2013 Apr 18. 被引量:1
  • 9Stutman RL, Codner M, Mahoney A, et al. Comparison of breast augmentation incisions and common complications[ J]. Aesthetic Plast Surg, 2012,36 (5) : 1096-104. 被引量:1
  • 10Serra-Renom J, Garrido MF, Yoon T. Augmentation mammaplas- ty with anatomic soft, cohesive silicone implant using the transax- illary approach at a subfascial level with endoscopic assistan ce[ J]. Plast Reconstr Surg, 2005,116(2) :640-645. 被引量:1

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部