期刊文献+

Design and Dynamic Modeling of a 2-DOF Decoupled Flexure-Based Mechanism 被引量:3

Design and Dynamic Modeling of a 2-DOF Decoupled Flexure-Based Mechanism
下载PDF
导出
摘要 Flexure mechanisms with decoupled characteristics have been widely utilized in precision positioning applications.However,these mechanisms suffer from either slow response or low load capability.Furthermore,asymmetric design always leads to thermal error.In order to solve these issues,a novel 2-DOF decoupled mechanism is developed by monolithically manufacturing sets of statically indeterminate symmetric(SIS) flexure structures in parallel.Symmetric design helps to eliminate the thermal error and Finite Element Analysis(FEA) results show that the maximum coupling ratio between X and Y axes is below 0.25% when a maximum pretension force of 200 N is applied.By ignoring the mass effect,all the SIS flexure structures are simplified to "spring-damper" components,from which the static and dynamics model are derived.The relation between the first resonant frequency of the mechanism and the load is investigated by incorporating the load mass into the proposed dynamics model.Analytical results show that even with a load of 0.5 kg,the first resonant frequency is still higher than 300 Hz,indicating a high load capability.The mechanism's static and dynamic performances are experimentally examined.The linear stiffnesses of the mechanism at the working platform and at the driving point are measured to be 3.563 0 N·μm-1 and 3.362 1 N·μm-1,respectively.The corresponding estimation values from analytical models are 3.405 7 N·μm-1 and 3.381 7 N·μm-1,which correspond to estimation errors of-4.41% and 0.6%,respectively.With an additional load of 0.16 kg,the measured and estimated first resonant frequencies are 362 Hz and 365 Hz,respectively.The estimation error is only 0.55%.The analytical and experimental results show that the developed mechanism has good performances in both decoupling ability and load capability;its static and dynamic performance can be precisely estimated from corresponding analytical models.The proposed mechanism has wide potentials in precision positioning applications. Flexure mechanisms with decoupled characteristics have been widely utilized in precision positioning applications.However,these mechanisms suffer from either slow response or low load capability.Furthermore,asymmetric design always leads to thermal error.In order to solve these issues,a novel 2-DOF decoupled mechanism is developed by monolithically manufacturing sets of statically indeterminate symmetric(SIS) flexure structures in parallel.Symmetric design helps to eliminate the thermal error and Finite Element Analysis(FEA) results show that the maximum coupling ratio between X and Y axes is below 0.25% when a maximum pretension force of 200 N is applied.By ignoring the mass effect,all the SIS flexure structures are simplified to "spring-damper" components,from which the static and dynamics model are derived.The relation between the first resonant frequency of the mechanism and the load is investigated by incorporating the load mass into the proposed dynamics model.Analytical results show that even with a load of 0.5 kg,the first resonant frequency is still higher than 300 Hz,indicating a high load capability.The mechanism's static and dynamic performances are experimentally examined.The linear stiffnesses of the mechanism at the working platform and at the driving point are measured to be 3.563 0 N·μm-1 and 3.362 1 N·μm-1,respectively.The corresponding estimation values from analytical models are 3.405 7 N·μm-1 and 3.381 7 N·μm-1,which correspond to estimation errors of-4.41% and 0.6%,respectively.With an additional load of 0.16 kg,the measured and estimated first resonant frequencies are 362 Hz and 365 Hz,respectively.The estimation error is only 0.55%.The analytical and experimental results show that the developed mechanism has good performances in both decoupling ability and load capability;its static and dynamic performance can be precisely estimated from corresponding analytical models.The proposed mechanism has wide potentials in precision positioning applications.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第4期688-696,共9页 中国机械工程学报(英文版)
基金 supported by National Natural Science Foundation of China (Grant No. 51175372) National Key Special Project of Science and Technology of China (Grant No. 2011ZX04016-011)
关键词 precision positioning flexure hinge DYNAMICS decoupled structure precision positioning,flexure hinge,dynamics,decoupled structure
  • 相关文献

参考文献20

  • 1CHOI B J, SREENIVASAN S V, JOHNSON S, et al. Design of orientation stages for step and flash imprint lithography[J]. Precision Engineering, 2001, 25(3): 192-199. 被引量:1
  • 2TIAN Yanling, SHIRINZADEH B, ZHANG Dawei. A flexure-based five-bar mechanism for micro/nano manipulation[J]. Sensors and Actuators A-Physical, 2009, 153(1): 96-104. 被引量:1
  • 3YAO Q, DONG J, FERREIRA P M. Design, analysis, fabrication and testing of a parallel-kinematic micropositioning XY stage[J]. International Journal of Machine Tools & Manufacture, 2007, 47(6): 946-961. 被引量:1
  • 4HESSELBACH J, RAATZ A. Compliant parallel robot with 6 DOF[C]//Microrobotics and microassembly III conference, Newton, MA, USA, October 29,2001: 143-150. 被引量:1
  • 5CHOI S B, HAN S S, HAN Y M, et al. A magnification device for precision mechanisms featuring piezoactuators and flexure hinges: Design and experimental validation[J]. Mechanism and Machine Theory, 2007, 42(9): 1184-1198. 被引量:1
  • 6HA J L, KUNG Y S, HU S C, et al. Optimal design of a micro-positioning Scott-Russell mechanism by Taguchi method[J]. Sensors and Actuators A-Physical, 2006, 125(2): 565-572. 被引量:1
  • 7LOBONTIU N, GARCIA E. Analytical model of displacement amplification and stiffness optimization for a class of flexure-based compliant mechanisms[J]. Computers and Structures, 2003, 81(32): 2797-2810. 被引量:1
  • 8HUA W, ZHANG Xianmin. Input coupling analysis and optimal design of a 3-DOF compliant micro-positioning stage[J]. Mechanism and Machine Theory, 2008, 43(4): 400-410. 被引量:1
  • 9DONG W, SUN L N, DU Z J. Design of a precision compliant parallel positioner driven by dual piezoelectric actuators[J]. Sensors and Actuators A-Physical, 2007, 135(1): 250-256. 被引量:1
  • 10TIAN Yanling, SHIRINZADEH B, ZHANG Dawei. Design and dynamics of a 3-DOF flexure-based parallel mechanism for micro/nano manipulation[J]. Microelectronic Engineering, 2010, 87(2): 230-241. 被引量:1

二级参考文献16

共引文献41

同被引文献35

引证文献3

二级引证文献12