期刊文献+

核电站电气柜抗震分析 被引量:1

Seismic Analysis on Electrical Cabinets Used in Nuclear Power Station
下载PDF
导出
摘要 采用有限元法,对某核电站用的电气柜及其安装底架进行了结构抗震计算分析。简单介绍了结构的力学建模、载荷条件和地震响应谱分析方法,计算得到了结构的固有频率、振型和地震载荷下的响应,并根据RCC—M规范要求进行应力评定。结果表明,电气柜及其安装底架的结构强度满足规范要求。本文的计算结果为电气柜的抗震设计提供了依据。 This paper did structural seismic analysis on electrical cabinets and its baseframe used in nuclear power plants, using the finite element method. It briefly introduced the structural mechanical model, load condition and seismic response spectrum analysis method, calculated the structural natural frequency, mode shape as well as the response to the seismic load, and evaluated the structural stress ac- cording to RCCM criteria. The results showed that the structural intensity of the electrical cabinet and its installation baseframe satisfied the requirements of the specification. And, the calculation result provided the basis for the seismic design of the electrical cabinets.
出处 《核电工程与技术》 2012年第2期5-8,共4页 Nuclear Power Engineering and Technology
关键词 核电站 电气柜 抗震分析 响应谱 应力评定 nuclear power station,electrical cabinets, seismic analysis,response spectrum,stress e-valuation
  • 相关文献

参考文献6

  • 1GB50267-1997,核电厂抗震设计规范[S].北京:国家地震局,1997. 被引量:17
  • 2HAF0215(1)核电厂的抗震设计与鉴定[S]. 被引量:1
  • 3GB50011-2002.建筑抗震设计规范[S].[S].,.. 被引量:18
  • 4RCC-M-2000压水堆核电站核岛机械设备设计和建造规则[S]. 被引量:1
  • 5刘兵山,黄聪等.Patran从人门到精通[M].北京:中国水利水电出版社.2003. 被引量:5
  • 6张永昌编著..MSC.Nastran有限元分析理论基础与应用[M].北京:科学出版社,2004:505.