期刊文献+

汽轮发电机灭磁时间特性的仿真计算 被引量:2

The simulation computation on the de-excitation time for the turbo-dynamo unit
下载PDF
导出
摘要 发电机灭磁是发电机发生故障时消除故障防止事故扩大的最后防线,发电机安全可靠和快速的灭磁能力直接决定了发电机主变压器等设备的安全水平.本文应用MATLAB软件对600MW级汽轮发电机组的灭磁时间特性进行了仿真分析,具体对比分析了该机组在线性、氧化锌和碳化硅非线性灭磁电阻配置情况下,以及各种工况条件下的灭磁时间特性,其结果对于灭磁系统设计具有实际指导意义. The de-excitation is the last protection line for the generator when it's brokendown. The reliable and quick de-excitation ability dominates the safety level of the generator. In this paper, we use MATLAB software to do simulation analysis for the 600 MW turbo-dynamo unit, concretely comparing and analyzing the de-excitation time, when the system is under the circumstance of linear, nonlinear zinc oxide and silicon carbide resistor configuration, as well as the variety of working conditions. The result has practical guidance for the de-excitation system design.
出处 《华中师范大学学报(自然科学版)》 CAS CSCD 北大核心 2012年第4期414-416,426,共4页 Journal of Central China Normal University:Natural Sciences
基金 国家自然科学基金资助项目(60571010)
关键词 600MW 汽轮发电机组 灭磁 计算机仿真 600 MW turbo-dynamo unit de-excitation computer simulation
  • 相关文献

参考文献6

  • 1梁建行.发电机灭磁系统几个技术要求的讨论[J].水电自动化与大坝监测,2005,29(3):45-50. 被引量:7
  • 2Johnson J P, Ehsani M, Guzelgunler Y. Review of sensor less methods for brushless DC motor[J]. Proceeding of the IEEE IAS Conference, 1999(1) :143-150. 被引量:1
  • 3Shao J, Nola D, Hopkins T. Improved direct back EMF de tection for sensorless brushless DC (BLDC) motor drives [J]. Proceeding of IEEE APEC, 2003(7): 300-305. 被引量:1
  • 4中华人民共和国国家标准局.GB/T7409.1/2/3-1997《同步电机励磁系统定义、电力系统研究用模型、大中型同步励磁系统技术要求》[S].北京:中国电力出版社,1997. 被引量:1
  • 5中华人民共和国国家标准局.DL/T650-1998《大型汽轮发电机自并励静止励磁系统技术条件》[S].北京:中国电力出版社,1998. 被引量:1
  • 6李基成编著..现代同步发电机励磁系统设计及应用[M].北京:中国电力出版社,2002:335.

二级参考文献5