摘要
为了证明基波串联谐振注入式混合有源滤波器的稳态补偿特性,利用谐波源谐波抑制函数作为它的稳态补偿特性评价指标,并通过MATLAB仿真软件进行仿真试验,结果证明:当加入这种混合有源滤波器时,整个系统的补偿特性很稳定,鲁棒性很好,不受电网的阻抗的影响。
In order to prove the steady-state compensation characteristics of fimdamental series resonance injection type of hybrid active filter, the harmonic control function of harmonic sources is used as the evaluation index of its steady compensation characteristic. Simulation study with simulation software MATLAB shows that: after joining this mixed active filter, the compensation characteristic of the entire system appears very stable and performs a good robustness, and without effect by the impedance of the power grid.
出处
《南方电网技术》
2012年第A01期52-55,共4页
Southern Power System Technology
关键词
谐波补偿基波串联谐振注入式混合有源滤波器无源滤波器组
compensation of harmonic
fundamental series resonance injection type
hybrid active filter
passive filters