摘要
介绍了实时操作系统(SAFERTOS)的特点,并将其与μC/OS-Ⅱ进行比较。以SAFERTOS的队列机制为基础,实现了邮箱和信号量机制。最后介绍了SAFERTOS在新型智能负荷监测仪中的应用。
This paper introduces the characteristics of real-time operation system SAFERTOS, and compares it with μC/OS-Ⅱ. Then describes how to realize mailbox and semaphore mechanisms based on the queue of SAFERTOS. Finally, it introduces the ap- plication of SAFERTOS in the new intelligent load testing instrument.
出处
《电子技术应用》
北大核心
2012年第7期23-25,29,共4页
Application of Electronic Technique