摘要 目的探讨多排螺旋CT肾移植供体静脉系统成像的最佳时间。方法 58例活体肾移植供体行16排螺旋CT多期增强扫描。在动脉期与实质期之间插入连续5个全肾扫描序列,分别测定各序列中双侧肾脏动、静脉的CT值,并计算同一序列中同侧肾静脉与肾动脉CT值的比值。结果肾脏扫描动脉期及动脉后I期延迟时间分别为(28.86±3.42)s和(47.36±4.56)s;肾静脉CT值在动脉后Ⅰ期最高,平均为(213.68±35.36)Hu(左侧)和(215.18±36.89)Hu(右侧)。肾静脉峰值均位于动脉后Ⅰ期(左侧74.1%,右侧70.7%)及动脉期(左侧25.86%,右侧29.31%)。肾静脉/动脉最大比值出现在动脉后I期几率最高,分别为左侧41.40%,右侧53.45%。结论以最小时间间隔(7.5s)扫描的动脉后I期为显示肾静脉系统的最佳时相。 Objective To determine the optimal renal vein delay time for scanning living renal donors with multi-slice helical CT imaging. Methods A total of 58 living renal donors underwent multiphase enhancement 16-slice helical CT scanning. Between the arterial and parenchymal phase, 5 continuous kidney series were inserted. The CT values of bilateral renal artery and vein in all series were measured and the ratio of homonymy renal vein to artery in the same series was calculated. Results The delay times of the artery phase and the 1st phase after the artery were (28. 86±3, 42) s and (47.36±4.56) s, respectively. The CT value of the renal vein was the highest in the 1st phase after the artery phase with the mean values of (213.68±35.36) Hu on the left side and (215. 18±36. 89) Hu on the right side. The peak value of the renal vein located in the 1st phase after artery phase (74. 1% on the left side and 70.7% on the right side) and the artery phase(25.86% on the left side and 29.31% on the right side). The maximum CT value ratio of the vein to artery mainly located in the 1st phase after artery phase(41.40% on the left side and 53.45% on the right side). Conclusion The 1st phase after the artery phase with the minimum interval of 7.5 s is the optimal phase to show the renal vein system.
出处 《江苏医药》 CAS CSCD 北大核心 2012年第13期1523-1525,共3页 Jiangsu Medical Journal
基金 南京市医学科技发展项目(YKK08067)
关键词 多排螺旋CT成像 肾静脉 Multi-slice helical CT imaging Renal vein
  • 相关文献

参考文献9

二级参考文献65

  • 1赵殿江,马大庆,贺文,林俊.多层螺旋CT后处理图像对亲属活体供肾术前的综合评价[J].临床放射学杂志,2006,25(10):932-935. 被引量:12
  • 2张龙江,王联营,沈文,祁吉.多层螺旋CT对活体肾移植供体术前综合评价的初步研究[J].中国医学影像技术,2007,23(4):585-588. 被引量:8
  • 3Kawamoto S,Montgomery RA,Lawler LP,et al.Multi-detector row CT evaluation of living renal donors prior to laparoscopic nephrectomy[J].Radio Graphics,2004,24 (2):453. 被引量:1
  • 4Raman SS,Pojchamarnwiputh S,Muangsomboon K,et al.Surgically relevant normal and variant renal parenchymal and vascular anatomy in preoperative 16-MDCT evaluation of potential laparoscopic renal donors[J].AJR Am J Roentgenal,2007,188(1):105. 被引量:1
  • 5Rydberg J,Kopecky KK,Tann M,et al.Evaluation of prospective living renal donors for laparoscopic nephrectomy with multisection CT:the marriage of minimally invasive imaging with minimally invasive surgery[J].Radio Graphics,2001,21(spec):S223. 被引量:1
  • 6Sahani DV,Rastogi N,Greenfield AC,et al.Multi-detector row CT in evaluation of 94 living renal donors by readers with varied experience[J].Radiology,2005,235(3):905. 被引量:1
  • 7Namasivayam S,Small WC,Kalra MK,et al.Multidetector-row CT angiography for preoperative evaluation of potential laparoscopic renal donors how accurate are we[J].Clin Imag,2006,30(2):120. 被引量:1
  • 8Kawamoto S,Montgomery RA,Lawler LP,et al.Multidetector CT angiography for preoperative evaluation of living laparoscopic kidney donors[J].AJR,2003,180(6):1633. 被引量:1
  • 9Kim JK,Park SY,Kim HJ,et al.Living donor kidneys:usefulness of multi-detector row CT for comprehensive evaluation[J].Radiology,2003,229(3):869. 被引量:1
  • 10Rastogi N,Sahani DV,Blake MA,et al.Evaluation of living renal donors:accuracy of three-dimensional 16-section CT[J].Radiology,2006,240(1):136. 被引量:1

共引文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部