期刊文献+

心电监护仪无创血压质量检测结果分析及讨论 被引量:5

Quality Control Analysis and Discussion on Noninvasive Blood Pressure Detection of ECG Monitor
下载PDF
导出
摘要 目的:通过心电监护仪的质量控制工作掌握在用监护仪的性能情况。方法:采用Fluke专业的质控设备对心电监护仪无创血压进行检测,对结果进行深入分析。结果:心电监护仪无创血压检测部分总体合格率较高,各品牌型号之间最大误差范围存在差异,不同测量段偏差数值也存在差异。结论:从品牌型号、不同测量段数值差异和使用年限差异3个方面对检测结果进行分析,对于找出影响无创血压检测结果的因素、提高仪器的合格率具有重要的意义。 Objective To control the performance situation of ECG monitors in use through the quality control work.Methods Fluke's professional quality control equipment was used to detect the ECG monitors' noninvasive blood pressure and the results were analyzed deeply.Results The total pass rate of the ECG monitors' noninvasive blood pressure measurement was high.There were differences among the maximum error ranges of ECG monitors from different brands or models,and also among the different measurement ranges.Conclusion The test results are analyzed from 3 aspects including brand or model,values differences among different measurement ranges and service age differences,which has great significance to identify the factors that affect the noninvasive blood pressure test results,and to improve the pass rate of the instrument.[Chinese Medical Equipment Journal,2012,33(6):114-115]
出处 《医疗卫生装备》 CAS 2012年第6期114-115,共2页 Chinese Medical Equipment Journal
关键词 心电监护仪 无创血压 质量检测 ECG monitor noninvasive blood pressure quality test