期刊文献+

采用圆洞标记法测量不规则硅橡胶印模的形变 被引量:1

Application of the pin-hole marker measurement of the irregular silicone impression accuracy
下载PDF
导出
摘要 目的:探索采用圆洞标记法测量口腔不规则硅橡胶印模形变的可行性。方法:模拟口腔临床基牙牙备体制作金属母模,表面有互成三角形的凸出圆形钢针。分别用2种硅橡胶材料制取印模,在突出钢针的对应部位形成圆洞标记点。用体式显微镜观察圆洞的形态变化,用圆心模拟软件标定坐标并测量位移,最后计算出2组印模的形变。结果:圆洞标记点边缘轮廓清晰、形态稳定,圆心坐标重复性好。2种硅橡胶样本48h的线性变化率分别为0.023%和0.042%。2个牙备体间,金玛克硅橡胶样本形变在1h时增大0.214%(45.1μm),48h时减小0.019%(4.0μm);3M硅橡胶样本形变在1h时增大0.087%(18.2μm),48h时减小0.09%(18.8μm)。结论:临床可采用圆洞标记法测量口腔不规则硅橡胶印模的形变。 PURPOSE: To investigate the feasibility of the pin-hole marker measurement of the irregular silicone dental impression accuracy. METHODS: The metal model simulating abutment preparations had triangle-formed circular needles on the surface. Two silicone impressions were made by the metal model with the corresponding pin-hole markers. The dimensional change of the markers was evaluated by stereomicroscope. The records were output by the software which could simulate the centre of a circle to measure the displacement and dimensional accuracy. RF^ULTS: The outline of pin-hole marker was clear and shape was stable. Values of center coordinates were repeated well. The percentage of linear dimensional change of two impression samples was 0.023% and 0.042% at 48h respectively. Between two abutment preparations, the percentage of linear dimensional change of Zhermeck silicone impression increased 0.214%(45.1μm) at lh and decreased 0.019%(4.0μm) at 48h while 3M silicone impression increased 0.087%(18.2μm) at lh and decreased 0.09%(18.8μm) at 48h. CONCLUSION: The pin-hole marker measurement of the irregular silicone impression accuracy was feasible.
出处 《上海口腔医学》 CAS CSCD 北大核心 2012年第3期262-265,共4页 Shanghai Journal of Stomatology
基金 上海市科学技术委员会资助项目(08DZ2271100) 上海市重点学科建设项目(T0202,S30206)~~
关键词 口腔印模 印模测量 印模形变 Dental impression Measurement Dimensional change
  • 相关文献

参考文献10

  • 1Rubel BS. Impression materials:a comparative review of impression materials most commonly used in restorative dentistry[J].Dental Clinics of North America,2007,(03):629-642. 被引量:1
  • 2Hamalian TA,Nasr E,Chidiac JJ. Impression materials in fixed prosthodontics:influence of choice on clinical procedure[J].Journal of Prosthodontics,2011,(02):153-160. 被引量:1
  • 3Faria AC,Rodrigues RC,Macedo AP. Accuracy of stone casts obtained by different impression materials[J].Braz Oral Res,2008,(04):293-298. 被引量:1
  • 4Kamegawa M,Nakamura M,Fukui Y. Direct 3-D morphological measurements of silicone robber impression using microfocus X-ray CT[J].Dcnt Mater J,2010,(01):68-74. 被引量:1
  • 5Aguilar ML,Elias A,Vizcarondo CE. Analysis of theedimcnsional distortion of two impression materials in the transfer of dental implants[J].J Orosthet Dent,2010,(04):202-209. 被引量:1
  • 6李烨侃,陈洁,魏斌.添加"正圆形标记"后对印模形变规律的影响[J].中国基层医药,2010,17(10):1299-1300. 被引量:1
  • 7Council on Dental Materials Devices. Revised american dental assnciation specification no,19 for non-aqueous,elastomeric dental impression materials[J].J An Dent Assoc,1977,(04):733-741. 被引量:1
  • 8缩聚硅橡胶印模材料——处于升级换代中的印模材料[J].上海口腔医学,2006,15(1):103-103. 被引量:1
  • 9白石柱,赵铱民,叶晓岚.几种常用印模材制取固定义齿模型的三维精度比较[J].实用口腔医学杂志,2001,17(3):239-242. 被引量:30
  • 10Walker MP,Petrie CS,Haj- Ali R. Moisture effect on polyether and polyvinylsiloxanc dimensional accuracy and detail reproduction[J].Journal of Prosthodontics,2005,(03):158-163.doi:10.1111/j.1532-849X.2005.04024.x. 被引量:1

二级参考文献19

  • 1Hassan AK.Dimensional accuracy of 3 silicone dental impression materials.East Mediterr Health J,2006,12(5):632-636. 被引量:1
  • 2Shah S,Sundaram G,Bartlett D,et al.The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques.J Dent,2004,32(8):653-658. 被引量:1
  • 3Nallamuthu N,Braden M,Patel MP.Dimensional changes of alginate dental impression materials.J Mater Sci:Mater Med,2006,17(12):1205-1210. 被引量:1
  • 4Piwowarczyk A,Ottl P,Buchler A,et al.In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making.Int J Prosthodont,2002,15(2):168-174. 被引量:1
  • 5American National Standards Institute/American Dental Association.Specification No.19 for dental elastomeric impression materials.J Am Dent Assoc,1977,94(4):733-741. 被引量:1
  • 6Walker MP,Petrie CS,Reem Haj-Ali,et al.Moisture effect on polyether and polyvinylsiloxane dimensional accuracy and detail reproduction.Journal of Prosthodontics,2005,14(3):158-163. 被引量:1
  • 7Johnson GH,Graig RC.Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models.J Prosthet Dent,1985,53(4):489-490. 被引量:1
  • 8Lepe X,Johnson GH.Accuracy of polyether and addition silicone after longterm disinfection.J Prosthet Dent,1997,78 (3):245-249. 被引量:1
  • 9Kios MP,Morgano SM,Stein RS,et al.Effects of chemical disinfectant solutions on the stability and accuracy of the dental impression complex.J Prosthet Dent,1996,76(4):356-362. 被引量:1
  • 10Petrie CS.Dimensional accuracy and surface detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under dry,moist,and wet conditions.J Prosthet Dent,2003,90 (4):365-372. 被引量:1

共引文献29

同被引文献9

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部