用标准表法检定特大口径流量计时温度影响的分析 被引量:1

The analysis of temperature influence on verification of super large diameter flowmeter with master meter method
下载PDF
导出
摘要 特大口径电磁流量计是一种新型的大口径水计量仪表,它的实流检定是制约其自身发展的关键因素.本文讨论了用标准表法检定特大口径流量计的原理,分析了温度对标准表法流量检定装置的影响,提出了误差修正方法和对检定装置设计的要求. Super-large diameter electromagnetic flowmeter is one of the new types of water flowmeter. Howerer its real-flow verification is the key obstacle to its development. In the thesis the theory of master meter method for verification of super-large diameter flowmeter is discussed and the temperature influence on the calibration rig with method of master meter is analysed. It is tried to find the method of error correction and to propose design requirements.
出处 《上海理工大学学报》 CAS 2000年第1期53-56,共4页 Journal of University of Shanghai For Science and Technology
关键词 误差修正 标准表法 流量计 温度 检定 verification temperature influence error correction master meter method
  • 相关文献

参考文献4

  • 1苏彦勋,范砧编著..液体流量标准装置[M].北京:中国计量出版社,1994:245.
  • 2曹玉璋,韩振兴编..热工基础[M].北京:航空工业出版社,1993:298.
  • 3林国编..工程数学方法[M].北京:机械工业出版社,1987:400.
  • 4肖明耀编著..实验误差估计与数据处理[M].北京:科学出版社,1980:242.