摘要 通过对LF精炼炉水冷炉盖的水路进行分析和研究,提出了对密排管式水冷炉盖水路进行优化。优化后,水冷炉盖的各水路出水水温降低到原设计要求,高温报警得到抑制,取得了显著地经济效益。 The analysis and research is based on of the water-cooled roof water route of the LF furnace So proposed to the water routes were optimized about the closelypackedtype water-cooledroof.Afteroptimization, The outlet water temperature of the water-cooled roof is reduced to the originalde signrequirements, suppressed the high temperatnre alarm, reduced the equipment downtime rate.designificant economic benefits.
出处 《科技风》 2012年第2期62-62,共1页
关键词 水冷炉盖 温度报警 水路优化 water--cooledroof temperaturealarm waterrouteoptimization
  • 相关文献

参考文献2

  • 1罗振才.炼钢机械[M]北京:冶金工业出版社,1989. 被引量:1
  • 2沈才芳;孙社成;陈建斌.电弧炉炼钢工艺与设备[M]北京:冶金工业出版社,2001. 被引量:1