中下段食管癌调强放疗布野方案剂量学比较 被引量:1

Dosimetric comparison of different schemes for arrange beams in intensity modulated radiation therapy for mid- and distal- esophageal carcinoma
原文传递
导出
摘要 目的分析中下段食管癌放疗中5野调强计划与7野调强计划的差异,寻找布野最佳方案。方法分别为接受调强放射治疗的12例中下段食管癌患者设计5野调强计划与7野调强计划,计划设计中要求95%的计划靶体积达到处方剂量。在每个病例中,分别比较两种计划的剂量体积直方图统计数据、剂量均匀指数、剂量适形指数。结果两种方案中,7野调强计划的靶区剂量适形度较好(t=2.681,P〈0.05);两种方案的剂量均匀指数、脊髓受照剂量、心脏受照剂量之间的差异无统计学意义;5野调强计划的双肺V5、V10、V15较低(t=-7.938、-12.055和-4.859,P均〈0.05)。结论在中下段食管癌放疗中,与7野调强计划相比,5野调强计划可以减少肺部的低剂量受照体积,同时提供可以接受的计划靶体积适形度,有助于减少肺部辐射损伤的发生概率,改善患者生存质量,值得在临床工作中推广应用。 Objective To analyze the difference between five-field plan and seven-field plan in intensity modulated radiation therapy for patients with mid- and distal-esophageal carcinoma, and to find out the optimal beam arrangement. Methods Five-field plan and seven-field plan were designed for each of 12 patients with mid- and distal-esophageal carcinoma. 95% of planning target volume was required to achieve prescription dose. Dose-volume histograms statistics, dose uniformity, and dose conformity in every patient were compared respectively. Results Superior dose conformity for planning target volume was shown in seven-field plan (t=2.681, P 〈0.05 ). Difference was not significant between uniformity in seven-field plan and that in five-field plan. Difference was not significant between doses received by organs at risk, such as spinal cord and heart, in seven-field plan and those in five-field plan. V5, V10, V15 of lungs in five-field plan were lower significantly than those in seven-field plan (t=-7.938, -12.055 and -4.859, all P〈0.05). Conclusions For patients with thoracic esophageal carcinoma treated by intensity modulate radiation therapy, compared with 7-fielded plan, the volume of lungs with lower dose could be reduced on the premise of acceptable planning target volume coverage by the application of five-plan. Therefore, radiation-induced lung injury occurrence probability would be reduced, and the patient's quality of life would be improved. Five-field plan would be worth applying in the clinical work.
出处 《国际放射医学核医学杂志》 2012年第2期121-123,F0003,共4页 International Journal of Radiation Medicine and Nuclear Medicine
关键词 食管肿瘤 放射治疗计划 计算机辅助 放射疗法 调强适形 病例对照研究 Esophageal neoplasms Radiotherapy planning, computer-assisted Radiation therapy, intensity-modulated Case-control studies
  • 相关文献

参考文献11

二级参考文献61

共引文献75

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部