个体化对比剂注射方案在256层CT冠状动脉成像中的应用 被引量:20

Application of the individual protocol of contrast medium injection in coronary angiography by 256-slice CT
下载PDF
导出
摘要 目的探讨个体化对比剂注射方案在256层CT冠状动脉成像中的应用价值。方法 100例临床怀疑冠心病需接受冠状动脉CT(CTA)检查者,按照对比剂注射方案个体化原则,对比剂总量(ml)=患者体重(kg),对比剂流率ml/s=对比剂总量/(扫描时间+8)ml/s,同样流率追加30ml生理盐水}进行冠脉CTA检查,测量升主动脉根部左冠开口处CT值并对冠状动脉的显示进行评分,分析对比剂注射方案个体化的可行性。结果按照个体化对比剂注射方案行冠脉CTA检查后,100例检查者升主动脉根部左冠开口处平均强化程度为(420.19±56.59)HU,冠状动脉显示评分得3分比例为88.78%,得2分比例为11.22%,无得1分者。结论个体化对比剂注射方案在256层CT冠状动脉成像中具有良好的应用价值。 Objective To investigate the application value of individual protocol of contrast medium injection in coronary angiography by 256-slice CT. Methods 100 subjects with clinically suspected coronary disease underwent coronary artery CT inspection, according to the individual principle of contrast agent injection plan, that is, total amount of contrast agent (ml) equals to patient's body weight (kg), discharge rate of contrast agent (ml/s) equals to total amount of contrast agent /(trace time +8) ml/s, and 30 ml physiological saline is supplemented if the discharge rate is similar. Subsequently, the CT value of left crown jaw opening in ascending aorta root was measured and the coronary artery's demonstration was graded so as to analyze the feasibility of individual plan of contrast agent injection. Results After the CTA inspection via the individuation of contrast agent injection plan, the mean strengthening degree of left crown jaw opening in ascending aorta root of these 100 patients was (420.19±56.59) HU. The coronary artery demonstrated scale was 3 in 88. 78%, 2 in 11.22%, and 1 in none. Conclusion Individuation of contrast media injection protocol is useful in heart coronary angiography by 256-slice CT.
出处 《医学影像学杂志》 2012年第5期757-760,共4页 Journal of Medical Imaging
关键词 冠状动脉 对比剂 体层摄影术 x线计算机 Tomography, X-ray computed Contrast media Coronary angiography
  • 相关文献

参考文献15

二级参考文献38

  • 1Fleischmann D. Use of high concentration contrast media:principles and rationale vascular district. Eur J Radio1,2003,45 :S88. 被引量:1
  • 2Brink JA. Use of high concentration contrast media (HCCM) :principles and rationale-body CT. Eur J Radio1,2003,45 :S53. 被引量:1
  • 3Herman S. Computed tomography contrast enhancement principles and the use of high-concentration contrast media. J Comput Assist Tomogr,2004,28 : 11. 被引量:1
  • 4de Monye C, Cademartiri F,de weert TT, et al. Sixteen-Detector row CT angiography of carotid arteries : Comparison of different volumes of contrast material with and without a bolus chaser, Radiology, 2005,237:555. 被引量:1
  • 5Suzuki H, Oshima H, Shiraki N, et al. Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT : a randomized study. Eur Radiol ,2004,14:2099. 被引量:1
  • 6Imhof H, Czerny C, Dirisamer A. Head and neck imaging with MDCT. Eur J Radiol,2003,45:23. 被引量:1
  • 7Becker CR, Hong C, Knez A, et al. Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol, 2003,38:690. 被引量:1
  • 8Cademartiri F, Motlet NR, van der Lugt A, et al. Intravenous contrast material administration at helical 16-detector row CT coronary angiography : Effect of iodine concentration on vascular attenuation. Radiology, 2005,236 : 661. 被引量:1
  • 9Leschka S,Wildermuth S, Boehm T, et al. Noninvasive coronary angiography with 64-section CT:Effect of average heart rate and heart rate variability on image quality. Radiology ,2006,241:378. 被引量:1
  • 10Herzog C, Aming-Erb M, Zangos S, et al. Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology ,2006,238:75. 被引量:1

共引文献85

同被引文献155

引证文献20

二级引证文献112

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部