摘要 在变换器型开关电源中,与电压控制模式开关电源相比,电流控制模式开关电源的电压调整率获得几个数量级的优化,负载调整率也有显著改善;但负载调整率仍劣于电压调整率,这成了目前变换器型开关电源的一种规律。 Compared with switching power supply with voltage-control mode, the voltage adjustment rate in current in switching power supply with current-control mode achieves optimization of several orders of magnitude, following the significant improvement in the load adjustment rate. However, the load adjustment rate is inferior to current adjustment rate, which is quite common with present-day convertor-type switching power supply.
作者 陈本竹
出处 《电源世界》 2012年第5期41-44,共4页 The World of Power Supply
关键词 VIPer22A 电压控制 电流控制 变换器型开关电源 负载调整率 电压调整率 VIPer22A, Voltage control, Current control, Convertor-type switching power supply, Load adjustment rate, Voltage adjustment rate