摘要 在试验条件无法满足的情况下(室外温度比较低,分别为-40℃、-50℃和-60℃),通过Fluent软件对KZ4AC型机车司机室加热系统的加热效率进行仿真计算。建立了KZ4AC型机车司机室物理模型及数学模型,运用试验手段验证了模拟结果的可靠性,为电力机车司机室加热系统的设计提供新的验证方法。结果表明:当室外温度分别为-40℃、-50℃、-60℃时,司机室温度达到要求所需加热时间分别为28 min、35 min和42 min,均满足标准要求。 In the case of outdoor temperature is very low (-40 ℃,-50 ℃ and -60 ℃ ) with which the laboratory could not meet,the Fluent software is used to simulate type KZ4Ac locomotive cab heating system efficiency. Physical and mathematical models of type KZ4Ac locomotive cab are set up. A new authentication method is designed for the electric locomotive cab heating system, the experiment results and the calculated results are in reasonable agreement. The results shows that when the outdoor temperature is -40 ℃,-50 ℃ and -60 ℃, the cab heating system uses 28 minutes,35 minutes and 42 minutes to reach the required temperature,and the three conditions are all meeting the standards.
出处 《电力机车与城轨车辆》 2012年第3期40-42,共3页 Electric Locomotives & Mass Transit Vehicles
基金 中国南车股份有限公司科技研发项目(2009NCK003)
关键词 电力机车 加热系统 仿真 Fluent软件 electric locomotive heating system simulation Fluent software
  • 相关文献

参考文献7

  • 1FOCTl2.2.056-1981,1520轨距铁路电力机车和内燃机车安全要求[S]. 被引量:1
  • 2HB)KTLIT04-98,电力机车--安全规范[S]. 被引量:1
  • 3曹小林.KZ4A.型客运电力机车司机室空调系统试验报告[R].长沙:中南大学,2010. 被引量:1
  • 4曹小林.KZ4A.型客运电力机车司机室空调系统计算报告[R].长沙:中南大学.2010. 被引量:1
  • 5黄卫星,李建明,肖泽仪编著..工程流体力学[M].北京:化学工业出版社,2009:292.
  • 6杨世铭,陶文铨编著..传热学[M].北京:高等教育出版社,2006:591.
  • 7温正,石良臣,任毅如编著..FLUENT流体计算应用教程[M].北京:清华大学出版社,2009:461.