期刊文献+

跨坐式单轨交通防雷效益评估分析 被引量:4

Benefit Evaluation of Lightning Protection for Straddle Monorail Traffic
下载PDF
导出
摘要 采用闪电定位(ADTD)系统监测资料,对重庆轻轨采取防雷保护措施前后人员生命损失风险和经济价值损失风险进行了评估计算。结果表明,跨坐式单轨采取雷电防护措施后,人员生命损失风险减少了96.98%,经济价值损失风险减少97.38%。自重庆轻轨2号线实际运行以来,截止2009年,其5km范围内各站点及区间年均闪电达到了12 862.75次,但由于采取了有效的防雷措施,未发生一起雷击事故。 Through an evaluation of life and economy losses caused by lightning in Chongqing light rail transit by using the monitoring data of ADTD lightning location system, it is clear that the losses of life and economy have decreased 96.98% and 97.38% respectively after the adoption of lightning protection system. Since the formal operation of Chongqing light rail transit Line 2, the yearly average lightning times have reached 12862.75 within 5 km of the line including all stops and sections. But there is no light- ning accident happening because of the perfect lightning protection measures.
出处 《城市轨道交通研究》 北大核心 2012年第5期36-41,45,共7页 Urban Mass Transit
关键词 单轨交通 防雷 人员生命损失风险 经济价值损失风险 monorail traffic lightning protection loss oflife loss of economy
  • 相关文献

参考文献4

二级参考文献13

共引文献32

同被引文献40

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;