摘要 A boron-lined proportional counter (BLPC) with a count rate limit close to the multi-wire proportional counter was manufactured to measure the mixed field around reactors. After measurement with a standard Am-Be neutron source (activity: 100 mCi), the results show that the operating voltage of the BLPC is 800 V, the plateau length is 100 V and the slope is 13.2%/100 V. The width and rise time of the output pulse of the BLPC are 1.26 μs and 370 ns, respectively. When the BLPC works at a count rate of 1.0 × 10 5 count/s, the pulse pile-up probability of the BLPC is 3.6%. A clear peak can be seen in the pulse height spectrum of the BLPC. and the performances illustrate that a BLPC working in pulse mode can serve as a source range detector of reactors. A boron-lined proportional counter (BLPC) with a count rate limit close to the multi-wire proportional counter was manufactured to measure the mixed field around reactors. After measurement with a standard Am-Be neutron source (activity: 100 mCi), the results show that the operating voltage of the BLPC is 800 V, the plateau length is 100 V and the slope is 13.2%/100 V. The width and rise time of the output pulse of the BLPC are 1.26 μs and 370 ns, respectively. When the BLPC works at a count rate of 1.0 × 10 5 count/s, the pulse pile-up probability of the BLPC is 3.6%. A clear peak can be seen in the pulse height spectrum of the BLPC. and the performances illustrate that a BLPC working in pulse mode can serve as a source range detector of reactors.
出处 《Chinese Physics C》 SCIE CAS CSCD 2012年第5期434-437,共4页 中国物理C(英文版)
关键词 BLPC mixed field count rate plateau curve BLPC mixed field count rate plateau curve
  • 相关文献

参考文献24

  • 1LIU Jiong, ZHANG Fan, ZHANG Rui et al. Nucl. Power Eng., 2003, 24(1): 231 (in Chinese). 被引量:1
  • 2ZHANG Jian-Ming, Olmstead R A. Nucl. Power Eng., 1999, :10(6): 507 (in Chinese}. 被引量:1
  • 3WANG Zhi-Guo, YUE Sheng. Nucl. Power Eng., 2002, 23(6): 24 (in Chinese). 被引量:1
  • 4Dauphin G, Duchene J. Duchene. Long Life Boron-Lined Proportional Counters Fitted to the Start-Up Range of the Nuclear Reactors. In French Atomic Energy Commission Teehnieal Report CEA-N-2299. Oif-gnr-Ivetter, France: CEA Centre d'Etudes Nucleuires de Saelay, 1983, 28. 被引量:1
  • 5Mazed D. Radiat. Meas., 2007, 42:245. 被引量:1
  • 6Victor V V, Raffaele G. Nucl. Instrum. Methods, 1974, 114(2): 205. 被引量:1
  • 7Robert J S, Guarnieri C R, Walker J C. Nucl. Instrum. Methods, 1975, 129(2): 447. 被引量:1
  • 8Zdzistaw P, Wojciech C. Nucl. Instrum. Methods, 1978, 157(2): 287. 被引量:1
  • 9Bogustaw B. Nucl. Instrum. Methods, 1980, 175(2 3): 431-439. 被引量:1
  • 10Beddingfield D H, Menlove H O, Johnson N H. Nucl. In- strum. Methods A, 1999, 422:35 200. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部