期刊文献+

双源CT前瞻性心电门控技术在小儿主动脉缩窄诊断中的应用

The application of prospective echocardiography-gated dual-source CT in children with aortic coarctation
原文传递
导出
摘要 目的探讨双源CT(DSCT)前瞻性心电门控技术在小儿主动脉缩窄诊断中的价值。方法对16例临床怀疑为主动脉缩窄的患儿行DSCT前瞻性心电门控心胸联合血管成像及心脏彩色多普勒血流显像(CDFI)检查。以手术或DSA结果为标准,采用X。检验比较DSCT和CDFI的诊断准确率。结果DSCT诊断主动脉缩窄16例,其中伴房间隔缺损(ASD)4例、室间隔缺损(VSD)9例、大动脉转位1例、主动脉弓发育不良3例、动脉导管未闭(PDA)7例、冠状动脉起源异常1例、支气管动脉扩张1例。CDFI诊断主动脉缩窄15例,主动脉弓离断1例,伴ASD4例、VSD9例、二叶型主动脉瓣(BAV)2例、大动脉转位1例、主动脉弓发育不良2例、PDA7例、支气管动脉扩张1例,未发现冠状动脉起源异常。与手术或DSA结果对照:DSCT和CDFI诊断准确率分别为97.2%(140/144)、97.9%(141/144),两者差异无统计学意义(X2=0.00,P〉0.05),DSCT和CDFI诊断敏感度均为93.2%(41/44),特异度分别为99.0%(99/100)和100.0%(100/100)。DSCT前门控平均有效辐射剂量为0.42mSv。结论DSCT前瞻性心电门控技术是诊断小儿主动脉缩窄的首选检查方法。 Objective To investigate the value of prospective ECG-gated dual-source CT (DSCT) in the diagnosis of coarctation of aorta ( CoA ) . Methods Sixteen patients clinically suspected of CoA underwent prospective ECG-gated DSCT angiography and color Doppler flow imaging (CDFI). The diagnostic accuracy of DSCT and CDFI were compared according to the results of operation or DSA. The non- parametric chi-square test was used for the statistics. Results Sixteen patients were diagnosed as CoA by DSCT, 4 were complicated with artial septal defect (ASD), 9 with ventricular septal defect (VSD), 1 with transposition of the great arteries, 3 with dysplasia of aortic arch, 7 with patent ductus arteriosus (PDA), 1 with abnormal origin of the coronary artery, 1 with bronchus artery dilation. Fifteen patients were diagnosed as CoA by CDFI, 1 was diagnosed as interruption of aortic arch. Four were complicated with ASD, 9 with VSD, 2 with bicuspid aortic valve ( BAV), 1 with transposition of the great arteries, 2 with dysplasia of aortic arch, 7 with PDA, 1 with bronchus artery dilation. Abnormal origin of the coronary artery was not found. The diagnostic accuracy of DSCT and CDFI were 97. 2% (140/144) and 97. 9% (141/144) respectively, there was no significant difference ( X2 = 0. 00, P 〉 0. 05 ). The sensitivity of DSCT and CDFI were both 93.2% (41/44), the specificity were 99. 0% ( 99/100 ) and 100. 0% ( 100/100). The mean effective radiation dose was 0.42 roSy. Conclusion Prospective ECG-gated DSCT is a good imaging technique for the diagnosis of aortic eoarctation in children.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2012年第5期401-404,共4页 Chinese Journal of Radiology
关键词 主动脉狭窄 体层摄影术 X线计算机 超声心动描记术 多普勒 彩色 血管 造影术 Aortic valve stenosis Tomography X-ray computed Echoeardiography, doppler, color Angiography
  • 相关文献

参考文献15

  • 1Shih MC, Tholpady A, Kramer CM, et al. Surgical and endovascular repair of aortic coarctation: normal findings and appearance of complications on CT angiography and MR angiography. AJR, 2006,187 : W302-W312. 被引量:1
  • 2Kimura-Hayama ET, Melendez G, Mendizabal AL, et al. Uncommon congenital and acquired aortic diseases: rote of multidetector CT angiography. Radiographies, 2010,30:79-98. 被引量:1
  • 3Haramati LB, Glickstein JS, Issenberg HJ, et al. MR imaging and CT of vascular anomalies and connections in patients with congenital heart disease: significance in surgical planning. Radiographics, 2002,22 : 337-347. 被引量:1
  • 4段艳华,王锡明,程召平,武乐斌,乌大尉,李剑,晁宝婷,柳澄.前瞻性心电门控双源CT冠状动脉成像在高心率患者中应用的可行性研究[J].中华放射学杂志,2009,43(7):714-718. 被引量:23
  • 5Cheng Z, Wang X, Duan Y, et al. Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol, 2010,20:2503-2511. 被引量:1
  • 6Thomas KE, Wang B. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method. Pediatr Radiol, 2008,38:645-656. 被引量:1
  • 7Salanitri GC. Intercostal artery aneurysms complicating thoracic aortic coarctation: diagnosis with magnetic resonance angiography. Australasian Radiol, 2007,51:78-82. 被引量:1
  • 8Paul JF, Rohnean A, Elfassy E, et al. Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source machine in infants and small children with congenital heart disease. Pediatr Radiol, 2011,41:244-249. 被引量:1
  • 9Xu L, Zhang Z. Coronary CT angiography with low radiation dose. Int J Cardiovasc Imaging, 2010,26 Suppl 1:17-25. 被引量:1
  • 10Ben Saad M, Rohnean A, Sigal-Clinqualbre A, et al. Evaluation of image quality and radiation dose of thoracic and coronary dual- source CT in 110 infants with congenital heart disease. Pediatr Radiol, 2009,39:668-676. 被引量:1

二级参考文献32

共引文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部