摘要
介绍了南郊水厂自动控制系统的组成及特点,通过对V型滤池设备故障分析,提出控制程序的优化方案,经对算法的研究和实际使用,解决了生产中存在的问题,达到了保证水质、节能降耗的功效。
This paper introduced the composition and characteristics of the Nanjiao Water Treatment Plant auto-control system.By analyzing the equipment problems of V-type filter,this paper brought forward the auto-control optimized plan.By studying and practical utilization of the calculation method,this paper also solved the existing problems in practical production,which secured the water quality and reduced the energy consumption.
出处
《给水排水》
CSCD
北大核心
2012年第5期102-104,共3页
Water & Wastewater Engineering
关键词
净水厂
自控系统
控制算法
V型滤池
PID控制
Water treatment plant
Auto-control system
Control calculation
V-type filter
PID control