摘要
针对市场上挤塑保温板的质量状况,对部分保温板生产企业进行的专项检查报告揭示了目前挤塑保温板的质量问题,特别是部分企业生产工艺不符合标准要求,其产品未经出厂检验或未按标准规定的技术要求检验,产品性能也不符合标准要求。检查报告还对现行的GB/T10801.2-2002国家标准提出了需要进一步改进和完善的建议。
For the quality conditions of the extruded insulation board market,a special inspection of some board production enterprises is conducted.The inspection report reveals quality problems of the extruded insulation board.Especially the production technology of the enterprise does not meet the standard requirements;the product is not tested before delivery or not according to the standards for technical requirements;the product performance does not meet the requirements of the standard.The inspection report also presents some improvements and suggestion for the current GB/T10801.2-2002 national standard.
出处
《江苏建材》
2012年第1期52-54,共3页
Jiangsu Building Materials
关键词
挤塑保温板
导热系数
保温性能
extruded insulation board
thermal conductivity
thermal performance