期刊文献+

一种新型测定铬(Ⅵ)非聚集比色传感器及其分析应用

A New Non-aggregation Colorimetric Sensor for the Detection of Cr(Ⅵ) and its Analysis Application
下载PDF
导出
摘要 基于Cr(Ⅵ)的氧化性对金纳米棒(GNRs)的轴端产生强的蚀刻作用及其引起的溶液颜色变化,开发了一种测定痕量Cr(Ⅵ)的非聚集比色传感器。该比色传感器线性范围为0.1μM-20μM,检出限为8.8×10-8M,除了Cu2+和Fe3+加入氨水可消除铁与铜的干扰外,常见的离子不干扰。本方法用于水体中Cr(Ⅵ)的比色检测,其结果与等离子体-质谱法相吻合。同时,探讨了非聚集比色传感测定Cr(Ⅵ) A non-aggregation based label free colorimetric sensor for the detection of Cr (VI) was has been developed based on the strong oxidization of Cr (VI) enables it to etch gold nanorods (GNRs) selectively at tips and colour change of the solution. The linear range and the limits of detection for the Cr (VI) are 0.10-20.0 pM and 8.8 ×10^4 M, respectively. The proposed colorimetric sensor has been applied to the detection of Cr (VI) in drinking water and sea water, and the results consisting with those obtained by inductively coupled plasma mass spectroscopy (ICP-MS). Moreover, the mechanism of colorimetric sensor for the detection of Cr (VI) was also discussed.
作者 蒋淑恋
出处 《漳州师范学院学报(自然科学版)》 2012年第1期64-70,共7页 Journal of ZhangZhou Teachers College(Natural Science)
基金 福建省质量技术监督局科技项目(FJQI2011006)
关键词 Cr(Ⅵ) 非聚集比色传感器 金纳米棒 Cr (VI) gold nanorod non-aggregation colorimetric sensor
  • 相关文献

参考文献31

  • 1Health assessment document for chromium(reⅥew Draft);EnⅥronmental Protection Agency:Springfield,VA,1983. 被引量:1
  • 2Eva M,Claudia F S,Marta T,et al.Determination of water-soluble hexavalent chromium in clinker samples bywavelength-dispersive x-ray fluorescence spectrometry after concentration in activated layers[J].Applied Spectroscopy,2010,64:547-551. 被引量:1
  • 3Han Z Q,Qi L,Shen G Y,et al.Determination of chromium(Ⅵ)by surface plasmon field-enhanced resonance light scattering[J].Anal.Chem,2007,79:5862-5868. 被引量:1
  • 4Ozgur D U,Mustafa T,Durali M,et al.3-Ethyl-4-(p-chlorobenzylidenamino-4,5-dihydro-1 H-1,2,4-triazol-5-one(EPHBAT)asprecipitant for carrier element free coprecipitation and speciation of chromium(III)and chromium(Ⅵ)[J].Journal of HazardousMaterials,2009,172:395-399. 被引量:1
  • 5Mohammad S H,Foroogh B.Cr(III)/Cr(Ⅵ)speciation determination of chromium in water samples by luminescence quenchingof quercetin[J].Journal of Hazardous Materials,2009,165:1062-1067. 被引量:1
  • 6Xiang Y,Mei L,Li N,et al.Sensitive and selective spectrofluorimetric determination of chromium(Ⅵ)in water by fluorescenceenhancement[J].Analytica Chimica Acta,2007,581:132-136. 被引量:1
  • 7M′arcio F B.Daniela P S,Maria V B Z,Development of a voltammetric sensor for chromium(Ⅵ)determination in waste watersample[J].Sensors and Actuators B,2007,123:902-908. 被引量:1
  • 8Ma gorzata J.Hybrid signal processing in voltammetric determination of chromium(Ⅵ)[J].Journal of Hazardous Materials2010,176:540-548. 被引量:1
  • 9Chen H,Du P,Chen J,et al.Separation and preconcentration system based on ultrasonic probe-assisted ionicliquid dispersiveliquid–liquid microextraction for determination trace amount of chromium(Ⅵ)by electrothermal atomic absorptionspectrometry[J].Talanta,2010,81:176-179. 被引量:1
  • 10Kazuhiro S,Shinichi O,Yukie N et al.Monoclonal antibody to trivalent chromium chelate complex and its application tomeasurement of the total chromium concentration[J].Anal.Chem.,2009,81(10):4005-4009. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部