期刊文献+

正常人眼全角膜光学质量调制传递函数的分析 被引量:3

An analysis of optical quality and modulation transfer function of normal human cornea
原文传递
导出
摘要 目的用调制传递函数(MTF)客观分析正常人眼全角膜的光学特性。方法横断面研究。选取200例(400眼),年龄为18-40岁拟做准分子激光手术的患者(柱镜度在-1.00以内),应用Sirius角膜地形图分析仪,经Phoenis分析软件模拟得出3、4、5、6、7mm角膜光学区域,校正角膜低阶像差后,在全角膜的垂直和水平子午线的MTF曲线上,选取5、10、15、20、25、30、35、40、45、50、55和60c/d空间频率的MTF值进行统计学描述.左右眼之间MTF值及斯特列尔比(SR)的比较采用配对t检验或符号秩和检验。结果MTF曲线在各角膜光学区域从低频至中频(5-15c/d)迅速下降,高频(〉15c/d)趋向缓和至零。随角膜光学区域的增大,MTF曲线逐渐降低。在3-6mm角膜光学区域时左右眼的SR值差异无统计学意义,呈镜像对称。7mm时右眼的SR值较左眼高,且差异有统计学意义忙-2.220,P=0.028)。3-5mm角膜光学区域时,水平子午线各空间频率的MTF值均大于垂直子午线的MTF值,差异有统计学意义。6-7mm在空间频率为20、25、30、35、40、45c/d时,水平子午线的MTF值小于垂直子午线,但差异无统计学意义。结论MTF能较客观、相对准确地对角膜成像质量进行评估描述。 Objective To use the modulation transfer function (MTF) to objectively analyze the optical quality of normal human cornea. Methods In this cross-sectional study, 200 patients (400 eyes) between18 and 40 years of age (cylindrical refraction less than -1.00 D) were enrolled. A Sirius corneal analyzer was used to measure the optical quality of the complete cornea. Different optical diameters, 3.0, 4.0, 5.0, 6.0 mm, and 7.0 mm, were analyzed for MTF and sterhl ratio (SR) values with Phoenix analysis software at different spatial frequencies (5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 c/d). A comparison of MTF values at the same spatial frequencies at vertical and horizontal meridians and SR values were analyzed with a paired t test or signed rank test. Results ①The MTF curve decreased rapidly from low to intermediate frequencies (5-15 c/d), then eased to zero at high frequencies (〉15 c/d). ②The MTF value decreased as the optical diameter increased. ③There was no significant difference in SR values between the right and left eyes in 3-6 mm optical diameters, showing a mirror symmetry. With a 7 mm optical diameter, the SR value of the right eye was significantly higher than that of the left eye (t=2.220, P=0.028). ④In 3-5 mm optical diameters, the MTF value of the horizontal meridian was higher than that of the vertical meridian, while in 6-7 mm diameters there was no significant difference in the MTF value between the vertical and horizontal meridians at most spatial frequencies (20, 25, 30, 35, 40, 45 c/d) though the MTF value of horizontal less than vertical. Conclusion The modulation transfer function can objectively evaluate and describe the image quality of the cornea that is relatively correct.
出处 《中华眼视光学与视觉科学杂志》 CAS 2012年第3期157-160,共4页 Chinese Journal Of Optometry Ophthalmology And Visual Science
关键词 调制传递函数 光学质量 角膜 斯特列尔比 Modulation transfer function Optical quality Cornea Sterhl ratio
  • 相关文献

参考文献19

  • 1李耀宇.眼波前引导的屈光手术学[M]北京:人民军医出版社,200954-58. 被引量:1
  • 2毕宏生,马晓华,蔡宛亭,解孝锋.对比敏感度和眩光敏感度在早期老年性白内障手术指征中的临床意义[J].中国实用眼科杂志,2006,24(4):404-406. 被引量:4
  • 3Liang J,Williams DR. Aberrations and retinal image quality of the normal human eye[J].Journal of the Optical Society of America,1997.2873-2883. 被引量:1
  • 4Villegas EA,Alc6n E,Artal P. Optical quality of the eye in the subjects with normal and excellent visual acuity[J].Investigative Ophthalmology & Visual Science,2008,(10):4688-4696.doi:10.1167/iovs.08-2316. 被引量:1
  • 5安连生.应用光学[M]北京:北京理工大学出版社,2008163. 被引量:1
  • 6Guirao A,Gonzá1ez C,Redondo M. Average optical performance of the human eye as a function of age in a normal population[J].Investigative Ophthalmology & Visual Science,1999.203-213. 被引量:1
  • 7Rovamo J,Mustonen J,Nassanen R. Two simple psychophysical methods for determining the optical modulation transfer function of the human eye[J].Vision Research,1994.2493-2502. 被引量:1
  • 8Castejón-Mochón JF,López-Gil N,Benito A. Ocular wave-front aberration statistics in a normal young population[J].Vision Research,2002.1611-1617. 被引量:1
  • 9Guriao A,Redondo M,Artal P. Optical aberrations of the human cornea as a function of age[J].Journal of the Optical Society of America A:Optics,Image Science and Vision,2000.1697-1702. 被引量:1
  • 10瞿佳,吕帆,毛欣杰,毛崇溶.视觉矫正质量评价研究[J].中华眼科杂志,2003,39(6):325-327. 被引量:42

二级参考文献25

  • 1Cheng H, Barnett JK, Vilupuru AS,et al. A population study on changes in wave aberrations with accommodation. J Vis, 2004, 4 : 272 -280. 被引量:1
  • 2Wang L, Koch DD. Ocular higher-order aberrations in individuals screened for refractive surgery. J Cataract Refract Surg, 2003,29: 1896-1903. 被引量:1
  • 3Applegate RA, Sarver EJ, Khemsara V. Are all aberration equal ? J Refract Surg, 2002, 18: 556-562. 被引量:1
  • 4Diaz- Douton F, Benito A, Pujol J, et al. Comparison of the retinal image quality with a Hartmann- Shack wavefront sensor and a double- pass instrument. Invest Ophthalmol Vis Sci, 2006, 47 : 1710-1716. 被引量:1
  • 5Cleary G, David J. Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lens. J Cataract Refract Surg, 2009, 35 : 265-272. 被引量:1
  • 6Weale RA. The senescence of human vision. Oxford, UK: Oxford University Press, 1992. 被引量:1
  • 7Thibos LN, Hong X. Clinical applications of the Shack- Hartmann aberrometer. Optom Vis Sci, 1999, 76: 817-825. 被引量:1
  • 8Villegas EA, Alcon E, Artal P. Optical quality of the eye in subjects with normal and excellent visual acuity. Invest Ophthahnol Vis Sci, 2008, 49 : 4688-4696. 被引量:1
  • 9Mrochen M, Kacmmerer M, Mierdel P, et al. Principles of tscheming aberrometry. J Refract Surg, 2000,16 : 570-571. 被引量:1
  • 10Rodrlguez P, Navarro R, Ganzalez L, et al. Accuracy and reproducibility of zywave,trace, and experimental aberrometers. J Refract Surg, 2004, 20: 810-817. 被引量:1

共引文献62

同被引文献13

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部