本文以硝基苯废水为研究对象,初步研究了不同TiO2/沸石负载量,不同光照时间等各种影响因素下硝基苯溶液COD的变化情况,从而确定出最佳工艺参数。确定处理的最佳效果为:催化剂投加量为待测溶液质量的2%,在254nm紫外灯在催化时3小时,初始pH为5,硝基苯初始浓度为50mg/L,所用光催化剂为TiO2/沸石,TiO2/沸石负载量为20%时效果最佳。
A preliminary study of different TiO2/zeolite load, different light time effect of various factors, and nitrobenzene CODCr change, so as to determine the optimum process parameters and reaction mechanism. Determine the best treatment forthe quality of catalyst is 2%of the analyte solution , at 254 nm UV lamp in catalytic three hours, Initial pH is 5, the nitrobenzene initial density is 50mg/L, as exhausted as TiO2 catalyst / zeolite, TiO2/zeolite with a capacity of 20%.
出处
《安徽建筑工业学院学报(自然科学版)》
2011年第6期88-90,共3页
Journal of Anhui Institute of Architecture(Natural Science)
基金
合肥工业大学重大项目预研专项(2010HGZY0007)
关键词
分子筛
TIO2
光催化降解
硝基苯
CODCR
zeolite molecular sieve
titanium dioxide
photocatalysis degrading
nitrobenzene