期刊文献+

典型钛白粉生产企业用水网络优化和设计

Design and analysis: a water network in titanium dioxid pigment by sulfate process
下载PDF
导出
摘要 硫酸法钛白粉生产行业是典型的耗水大户,具有较大的节水潜力,目前国内外对该行业节水研究较少。通过对某钛白粉厂用水网络现状的调研分析,本文采用数学规划法对用水网络进行了优化设计。通过建立优化模型,将各单元排水进行最大限度的回用,增加水的使用次数,降低新鲜水用量。研究结果表明,用水网络改造后,新鲜水消耗量和废水排放量分别比改造前减少90t/h,节水率达到36%。 The sulfate process titanium dioxide production has a huge consumption of fresh water with enormous capacity to water saving. However, study on the technology and mechanism to water saving did not be concerned enough. After analyzed based on the survey of one titanium dioxide production factory, author adopted mathematical programming to optimize the water network of the factory. With established the optimization model, the water reuse was sharply increased, the demand of fresh water was reduced. Applied the algorithm of the prioritization scheme, the freshwater consumption and wastewater discharge were reduced by 90t/h compared with the current water system, water con- servation rate achieving 36%.
出处 《安徽建筑工业学院学报(自然科学版)》 2011年第6期68-71,共4页 Journal of Anhui Institute of Architecture(Natural Science)
基金 "水体污染控制与治理"国家科技重大专项(2009ZX07317-005) 中日国际科技合作项目(2009DFA92140) 上海市国际科技合作基金项目(09160708000)
关键词 钛白粉 数学规划 节水 网络优化 sulfate process titanium pigment mathematical programming water saving network optimization
  • 相关文献

参考文献12

二级参考文献35

  • 1Takama N, Kuriyama T, Shiroko K, et al. Optimal water allocation in a petroleum refinery. Comp Chem Eng, 1980, 4(4) : 251 -258 被引量:1
  • 2Wang Yaping, Smith R. Wastewater Minimization. Chem Eng Sci, 1994, 49 (7) : 981 - 1 006 被引量:1
  • 3Bagajewicza M, Rivas M, Savelskib M. A robust method to obtain optimal and sub-optimal design and retrofit solutions of water utilization systems with multiple contaminants in process plants. Comp Chem Eng, 2000, 24 : 1 461 - 1 466 被引量:1
  • 4Savelskib M, Bagajewicza M. On the optimality conditions of water utilization systems in process plants with single contaminants. Chem Eng Sci, 2000, 55 (22): 5 035 - 5 048 被引量:1
  • 5Savelskib M, Bagajewicza M. On the necessary conditions of optimality of water utilization systems in process plants with multiple contaminants. Chem Eng Sci, 2003, 58 (24): 5349-5362 被引量:1
  • 6Alva-Argaez A, Kokossis A C, Smith R. Wastewater minimization of industrial systems using an integrated approach. Comp Chem Eng, 1998, 22 (Suppl) : S741 - 744 被引量:1
  • 7Alva-Argaez A, Vallianatos A, Kokossis A C. A multicontaminant transhipment model for mass exchange networks and wastewater minimisation problems. Comp Chem Eng, 1999, 23:1 439 -1 453 被引量:1
  • 8Karuppiah R, Ignacio E G. Global optimization for the synthesis of integrated water systems in chemical processes. Comp Chem Eng, 2006, 30:650 -673 被引量:1
  • 9Koppol A, Bagajewicza M. On zero water discharge solutions in the process industry. Adv Environ Res, 2003, 8 (2) : 151 - 171 被引量:1
  • 10Kuo W C J, Smith R. Designing for the interactions between water-use and effluent treatment. Trans IchemE, Part A , 1998, 76(3) : 287 -301 被引量:1