摘要
以甘露醇作为钛掩蔽剂,用铬天青-S作为显色剂测定钛合金中铝的方法,成功解决了传统分析中须沉淀分离来消除干扰的问题,简化分析手续,缩短分析时间,测定结果准确。
Taking mannitol as a masking agent for titanium and chrome azurol S as chromogenic agent, aluminum contents are measured in titanium alloy. This method needn't eliminate interference by precipitation separation just as in the traditional analysis which is simple in analysis procedure, short in analysis time and accurate in determining results.
出处
《特钢技术》
2012年第1期49-51,共3页
Special Steel Technology
关键词
钛合金
铬天青-s分光光度法
铝含量
Titanium alloy Chrome azurol S photometric method Aluminum content