低管电压技术在双源64层CT冠状动脉成像检查中的应用 被引量:12

The Application of Low kV Scanning in Dual-source 64-slice Coronary CTA Examination
下载PDF
导出
摘要 目的探讨降低管电压对体质指数(BMI)在正常范围内的患者进行双源CT冠状动脉(CTA)检查的临床应用价值。方法将36例BMI在正常范围内并进行冠状动脉CTA检查的患者随机分成两组,A组管电压采用常规扫描120kV;B组管电压采用100kV,均采用回顾性心电门控螺旋扫描。对两组图像的血管强化程度、重建血管清晰度以及辐射剂量进行分析评价。结果 36例患者检查均成功,图像质量分级与kV剂量之间差异无统计学意义(χ2=2.707,P=0.258),两组间平均有效剂量差异有统计学意义(t=8.618,P=0.000),两组各分支冠脉管腔内CT值之间差异均有统计学意义。结论对BMI在正常范围内的患者,冠状动脉CTA采用100kV检查,在保证图像质量的同时可明显降低辐射剂量,减少对患者的损伤,同时还有降低对比剂使用剂量的空间。 Objective To evaluate the clinical application of low kV scanning in coronary dual - source CT CTA examination in patients with normal body mass index. Methods 36 patients with normal BMI were ran- domly divided into two groups, A group of conventional scanning tube voltage 120kV, tube current with 420mAs/Rot; B group of tube voltage with 100kV, tube current by 360mAs/Rot, are used retrospectively ECG - gated spiral scanning. Results 36 patients were successfully inspected. Grading and kV image quality showed no significant difference between two groups ( X2 = 2. 707, P = 0.258 ) Average effective dose between the two groups were significantly different (t = 8. 618, P = 0. 000). Coronary luminal CT values in 2 groups showed significant differences. Conclusion For patients with normal BMI,coronary CTA using 100kV check can ensure image quality ,reduce the radiation dose and injury to patients.
出处 《宁夏医科大学学报》 2012年第2期128-130,共3页 Journal of Ningxia Medical University
关键词 冠状动脉成像 低剂量 X线计算机 体层摄影术 coronary angiography low dose X - ray computed tomography
  • 相关文献

参考文献5

  • 1Brenner DJ,Hall FJ.Computed tomography-an increasing source of radiation exposure[J].N Enj Med,2007,357(22):2277-2284. 被引量:1
  • 2Budolf MJ,Achenbach S,Blumenthal RS,et al.Assessment of coronary artery disease by cardiac computed tomography a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention,Council on Cardiovascular Radiology and Intervention,and Committee on Cardiac Imaging,Council on Clinical Cardiology[J].Circulation,2006,114(16):1761-1791. 被引量:1
  • 3张森,杜湘珂,李剑颖.心电图调制电流对于容积CT心脏扫描图像质量及曝光剂量影响的评估[J].中华放射学杂志,2006,40(9):974-976. 被引量:45
  • 4Morcos SK,Thomsen HS.Adverse reactions to Iodinated contrast media[J].Eur Radiol,2001,11(7):1267 -1275. 被引量:1
  • 5Briguori C,Airoldi F,Morici N,et al.New pharmacological protocols to prevent or reduce contrast media nephropathy[J].Minerva Cardioangiol,2005,53(1):49 -58. 被引量:1

二级参考文献4

共引文献44

同被引文献76

引证文献12

二级引证文献71

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部