期刊文献+

含牛血清蛋白人工唾液对纯钛腐蚀性能的影响研究 被引量:1

Effects of artificial saliva with albumen on corrosion behavior of titanium
下载PDF
导出
摘要 目的观察纯钛在含蛋白人工唾液中腐蚀性能的变化。方法制备纯钛试样,分别以Fusayama人工唾液(对照组,n=3)和加入0.01%、0.05%牛血清蛋白的Fusayama人工唾液(实验组1和实验组2,n=3)处理纯钛试样。采用电化学方法进行Tafel曲线测试,分析在含蛋白人工唾液中纯钛试样腐蚀性能的变化。结果 Tafel曲线测试结果显示:对照组、实验1组和实验2组纯钛试样的自腐蚀电位分别为(-349.1±19.6)、(-325.2±18.8)、(-218.2±12.5)mV,自腐蚀电流密度分别为(3.57±0.52)、(3.52±0.29)、(3.64±0.70)×10-2A/cm2。统计学分析结果显示:三组间自腐蚀电流密度比较差异无统计学意义(P>0.05);实验2组纯钛试样的自腐蚀电位显著高于对照组,差异有统计学意义(P<0.05)。结论含牛血清蛋白人工唾液影响纯钛金属材料的腐蚀性能,可能与其自腐蚀电位的改变有关。 Objective To investigate the corrosion behavior of titanium in artificial saliva with albumen.MethodsSamples of titanium were prepared,and were treated with Fusayama artificial saliva(control group,n=3),Fusayama artificial saliva added with 0.01% bovine serum albumin(experiment group 1,n=3) and Fusayama artificial saliva added with 0.05% bovine serum albumin(experiment group 2,n=3) respectively.Tafel curve tests were performed with electrochemical methods,and the change of corrosion behavior of titanium in artificial saliva with albumen was analysed.Results Tafel curve tests indicated that the values of self-corrosion potential of titanium samples were(-349.1±19.6)mV,(-325.2±18.8) mV and(-218.2±12.5) mV respectively,and the values of self-corrosion current density of titanium samples were(3.57±0.52)×10-2 A/cm2,(3.52±0.29) ×10-2 A/cm2 and(3.64±0.70)×10-2 A/cm2 respectively in control group,experiment group 1 and experiment group 2.Statistical analysis revealed that there was no significant difference in the values of self-corrosion current density among three groups(P0.05),and the value of self-corrosion potential in experiment group 2 was significantly higher than that in control group(P0.05).ConclusionArtificial saliva with albumen may influence the corrosion behavior of titanium,which may be related to the change of self-corrosion potential of titanium.
出处 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2012年第3期293-295,共3页 Journal of Shanghai Jiao tong University:Medical Science
基金 上海市科委基金(08DZ2271100) 上海市重点学科建设项目(S30206)~~
关键词 纯钛 腐蚀性能 蛋白 人工唾液 titanium corrosion albumen artificial saliva
  • 相关文献

参考文献11

  • 1闫嘉群,李天侠,徐文秀,于肖洋.纯钛在不同漱口液中耐腐蚀性能的研究[J].口腔医学,2009,29(2):77-80. 被引量:6
  • 2Nakagawa M,Matsuya S,Shiraishi T,et al.Effect of fluorideconcentration and pH on corrosion behavior of titanium for dental use[J].J Dent Res,1999,78(9):15681572. 被引量:1
  • 3Nakagawa M,Matono Y,Matsuya S,et al.The effect of Pt and Pdalloying additions on the corrosion behavior of titanium in fluoride-containing environments[J].Biomaterials,2005,26(15):2239-2246. 被引量:1
  • 4Williams RL,Brown SA,Merritt K.Electrochemical studies onthe influence of proteins on the corrosion of implant alloys[J].Biomaterials,1988,9(2):181-186. 被引量:1
  • 5Wataha JC,Nelson SK,Lockwood PE.Elemental release from dentalcasting alloys into biological media with and without protein[J].Dent Mater,2001,17(5):409-414. 被引量:1
  • 6Hallab NJ,Skipor A,Jacob JJ.Interfacial kinetics of titanium-andcobalt-based implant alloys in human serum:metal release andbiofilm formation[J].J Biomed Mater Res A,2003,65(3):311-318. 被引量:1
  • 7Ide K,Hattori M,Yoshinari M,et al.The influence of albumin oncorrosion resistance of titanium in fluoride solution[J].Dent MaterJ,2003,22(3):359-370. 被引量:1
  • 8曹楚南,张鉴清著..电化学阻抗谱导论[M].北京:科学出版社,2002:194.
  • 9赵立臣,崔春翔,刘双进,张喆.三种新型亚稳β钛合金在人工模拟体液中的腐蚀行为[J].中国组织工程研究与临床康复,2007,11(9):1686-1688. 被引量:3
  • 10Takemoto S,Hattori M,Yoshinari M,et al.Corrosion behavior andsurface characterization of titanium in solution containing fluorideand albumin[J].Biomaterials,2005,26(8):829-837. 被引量:1

二级参考文献16

共引文献7

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部