摘要 对一种结合剪断法和后向散射法测量微纳光纤传输损耗的反射式剪断法进行了优化。通过增加分光耦合器和探测器,用气凝胶固定尾纤,消除了光源波动和尾纤摆动对实验测试的影响。利用该方法测量微纳光纤传输损耗与直径的关系,实验结果表明改进后的方法,测量结果更稳定。 A new method called reflex-cut-back for testing the transmission loss of micro/nano fiber(MNF),which was designed based on combining the methods of cut-back and backscatter,was optimized.By adding coupler and power meter,the influence of source fluctuation and MNF-pigtail swing was eliminated by fixing the MNF-pigtail with aerogel.The relations between the transmission loss and different diameters of MNF were tested with this optimized scheme,and experimental results show that more stable test results could be obtained.
出处 《半导体光电》 CAS CSCD 北大核心 2012年第1期62-64,69,共4页 Semiconductor Optoelectronics
基金 西北工业大学基础研究基金资助项目(G9KY1018/09)
关键词 光纤光学 微纳光纤 损耗测试 剪断法 fiber optics micro/nano fiber loss testing cut-back