摘要
探讨准确测量烟气含湿量的方法,采用干湿球法、重量法、阻容法、激光法同步比对测量典型温湿度污染源烟气的含湿量,通过监测结果分析,提出了不同测量方法在实际烟气测量中的准确性和适用性,为准确、规范测定烟气含湿量提供技术依据。
The methods for humidity of flue gas were discussed such as wet-and-dry-bulb thermometer,gravimetric method,resistive and capacitive moisture measurement and laser method synchronously used in a typical emission pipe of flue gas to measure humidity.Based on the results of practical accuracy and applicability of each method,some suggestion was made for providing technical support to determinate humidity in flue gas.
出处
《环境监测管理与技术》
2012年第1期66-69,共4页
The Administration and Technique of Environmental Monitoring
基金
中国环境监测总站转型科研基金资助项目(CNEMC-ZXKY2009-011)
关键词
烟气含湿量
干湿球法
重量法
阻容法
激光法
Flue gas moisture content; Measurement with wet-and-dry-bulb thermometer; Gravimetric method; Resistive and capacitive moisture measurement; Laser method