摘要 目的用标准血液涂片对血液分析仪异常结果复检,建立血液分析仪血细胞显微镜复检标准,提高血细胞分析结果准确性。方法应用推片的角度固定在18。,血液的量固定在5μL,制作出标准的血液涂片。进行血细胞显微镜复检。通过对l,100份标本结果的数据分析,评价该标准的可行性和可靠性。结果仪器检测有30.1%的血液分析标本需要复查。血细胞分析仪与显微镜复检结果具有一定差异,仪器不能完全代替显微镜涂片检查,尤其是用标准血液涂片进行镜检更佳。普通血涂片和标准血涂片比较,幼稚细胞、中性粒细胞、淋巴细胞、单核细胞P〈0.0l,有显著性差异。结论制定血细胞显微镜复检标准,用推片的角度固定在18。血液的量固定在5μL,制作出标准的血液涂片。更有利于提高血细胞检查准确性,在疾病的临床诊断和治疗中具有重要价值。 Objective Using standard blood smears to re-examine the abnormal results of hematology analyzer, and to establish the re-examination standard for blood cell microscopy of hematology analyzer to improve the accuracy of the blood analysis results. Method Using the pushing slide which the angle is fixed on 18° and blood volume is fixed on 5 μ L to make standard blood smear, and re-examine blood cells with microscopy.Through analyzing the data results of 1,100 specimens,evaluate the feasibility and reliability of the standard. Result 30.1% of the instrument detects of the samples need to be. reviewed.Hematology analyzer have certain differences with the microscope review, the instrument cannot replace microscopic smear examination. Especially, using the standard blood smears is much better.Compared with normal blood smear, the standard blood smear's immature cells,neutrophils,lymphocytes and mononuclear cells(P〈0.0 1) are significantly different. Conclusion Developing the re-examination standard for blood cell microscopy, with the pushing slide which the angle is fixed on 18° and blood volume is fixed on 5 μ L to make standard blood smear, can better improve the accuracy of blood cell examine.The standard has great value in disease diagnosis and treatment.
出处 《中国血液流变学杂志》 CAS 2011年第4期709-711,共3页 Chinese Journal of Hemorheology
关键词 血液分析仪 标准血液涂片 显微镜复检 hematology analyzer standard blood smear microscopy re-examination
  • 相关文献

参考文献6

  • 1孙芾,赵素荣.全自动白细胞分类仪的评价[J].中华医学检验杂志,1992,15(6):366-368. 被引量:10
  • 2Robertson EP,Lai HW,Wei DC.An evaluation of leucocyte analysis on the Coulter STKS[J].Clin Lab Haematol,1992,14(1):53-68. 被引量:1
  • 3丛玉隆主编..当代血液分析技术与临床[M].北京:人民卫生出版社,1997:223.
  • 4刘成玉,林发全主编..临床检验基础[M].北京:中国医药科技出版社,2015:360.
  • 5刘孝武,赵会芹,贺信祥,李金良,刘学军,郭洪海,王英.制作标准化血液涂片建议与研究[J].中国血液流变学杂志,2007,17(1):130-131. 被引量:13
  • 6叶应妩,王毓三主编,中华人民共和国卫生部医政司编..全国临床检验操作规程 第2版[M].南京:东南大学出版社,1997:621.

二级参考文献4

共引文献21

同被引文献6

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部