期刊文献+

不同栓塞程度对颅内动脉瘤介入治疗后囊内血流动力学影响的数值模拟研究 被引量:3

Impact of different coil packing densities on intra-aneurysmal hemodynamics during embolization of intracranial aneurysm:a numerical simulative study
下载PDF
导出
摘要 目的研究弹簧圈栓塞不同栓塞程度下颅内动脉瘤内血流动力学变化,为临床血管内治疗策略的制定提供理论依据。方法基于脑动脉瘤血管造影的三维血管成像,在不同栓塞状态下,重建动脉瘤的三维模型,采用Ansys CFX软件包分析血流速度、壁面切应力(WSS)、压力分布和流场情况。结果与治疗前相比,动脉瘤顶端部分栓塞后瘤体明显缩小,瘤顶低WSS区域减小,瘤体内涡流减少但流速无变化,同时造成瘤顶部平均WSS增大为2.13 Pa;而继续栓塞后,使动脉瘤整体壁面切应力显著下降,残留瘤颈远端流速明显降低;无论栓塞与否,动脉瘤流入道血管壁的壁面压力均无明显变化。结论颅内动脉瘤囊内血流动力学变化受弹簧圈栓塞程度及其在瘤体内分布的影响。 Objective To investigate the impact of different coil packing densities on intra-secular hemodynamics during embolization of intracranial aneurysm,so as to provide the theoretical evidence for endovascular treatment of intracranical aneurysms.Methods Based on digital subtraction angiography image data,the vessel numerical models with different packing densities were constructed using computational fluid dynamics software.The hemodynamic parameters,including the wall shear stress(WSS) and flow steamline and pressure,were obtained from the numerical simulation using Ansys CFX software.Results The aneurysm volume and low WSS area in the aneurysm sac were decreased after the first session of embolization compared with before treatment;the vortex in the aneurysm was decreased and the aneurysmal flow velocity had no significant changes.Meanwhile,the WSS at the aneurysm dome increased to 2.13 Pa.Continuous embolization greatly decreased the overall aneurysmal flow velocity and the aneurysmal flow velocity at the distal part of the residual aneurysm neck.The average wall pressure of the inflow tract had no noticeable changes before and after embolization.Conclusion The intra-saccular hemodynamics during embolization of intracranial aneurysm can be influenced by the coil packing density and coil distribution in the aneurysm.
出处 《第二军医大学学报》 CAS CSCD 北大核心 2012年第2期195-199,共5页 Academic Journal of Second Military Medical University
基金 国家自然科学基金(81171092)~~
关键词 颅内动脉瘤 介入治疗 治疗性栓塞 血流动力学 intracranial aneurysm interventional therapy therapeutic embolization hemodynamics
  • 相关文献

参考文献18

  • 1Mut F,Lhner R,Chien A,Tateshima S,Viňuela F,Putman C,etal.Computational hemodynamics Framework for the analysis of cer- ebral aneurysms[J].Int J Numer Method Biomed Eng,2011,27:822-839. 被引量:1
  • 2Jou L D,Mawad M E.Hemodynamic effect of Neuroform stent onintimal hyperplasia and thrombus formation in a carotid aneurysm[J].Med Eng Phys,2011,33:573-580. 被引量:1
  • 3Yoon W.Current update on the randomized controlled trials of in-tracranial aneurysms[J].Neurointervention,2011,6:1-5. 被引量:1
  • 4Morales H G,Kim M,Vivas E E,Villa-Uriol M C,Larrabide I,Sola T,et al.How do coil configuration and packing density influ- ence intra-aneurysmal hemodynamics?[J].AJNR Am J Neuro-radiol,2011,32:1935-1941. 被引量:1
  • 5Lai L,Morgan M K.The impact of changing intracranial aneurysmpractice on the education of cerebrovascular neurosurgeons [J].JClin Neurosci,2012,19:81-84. 被引量:1
  • 6Liu J M,Zhao W Y,Zhang X,Xu Y,Hong B,Huang Q H.Patholo-gy of stented common carotid aneurysm in dogs.Comparison be-tween stenting and stent-assisted coiling[J].Interv Neuroradiol,2005,11:333-340. 被引量:1
  • 7Kawanabe Y,Sadato A,Taki W,Hashimoto N.Endovascular occlu-sion of intracranial aneurysms with Guglielmi detachable coils:cor-relation between coil packing density and coil compaction[J].ActaNeurochir(Wien),2001,143:451-455. 被引量:1
  • 8黄清海,杨鹏飞,张星,施洋,邵雪明,刘建民.血流转向装置对动脉瘤血流动力学影响的数值模拟研究[J].中华医学杂志,2010,90(15):1024-1027. 被引量:11
  • 9陈军,黄清海,刘建民,陈家亮,王盛章,洪波,许奕,赵文元.颅内未破裂与破裂动脉瘤血流动力学数值模拟研究[J].中国脑血管病杂志,2010,7(12):626-630. 被引量:14
  • 10Cha K S,Balaras E,Lieber B B,Sadasivan C,Wakhloo A K.Mod-eling the interaction of coils with the local blood flow after coil em-bolization of intracranial aneurysms[J].J Biomech Eng,2007,129:873-879. 被引量:1

二级参考文献26

  • 1穆士卿,杨新健,张莹,吕明,吴中学,李海云,王盛章,丁光宏.颅内动脉瘤的三维数值模拟分析[J].中国微侵袭神经外科杂志,2008,13(10):459-462. 被引量:12
  • 2赵丛海,李淼,史万超,王捷,赵军伟,殷文毅,丁光宏,杨新健.颅内动脉瘤内涡流的血流动力学研究[J].中华实验外科杂志,2006,23(12):1447-1449. 被引量:17
  • 3Shojima M, Oshima M, Takagi K, et al. Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms. Stroke , 2004,35:2500-2505. 被引量:1
  • 4Liu JM, Zhao WY, Zhang X, et al. Pathology of stented common carotid aneurysm in dogs. Comparison between stenting and stent- assisted coiling. Intervent Neuroradiol, 2005, 11:334-340. 被引量:1
  • 5Kim M, Taulbee DB, Tremmel M, et al. Comparison of two stents in modifying cerebral aneurysm hemodynamics. Ann Biomed Eng, 2008, 36:726-741. 被引量:1
  • 6Zenteno MA, Santos-Franco JA, Freitas-Modenesi JM, et al. Use of the sole stenting technique for the management of aneurysm in the posterior circulation in a prospective series of 20 patients. J Neurosurg, 2008, 108 : 1104-1118. 被引量:1
  • 7Wanke I, Forsting M. Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neureradiology, 2008, 50:991-998. 被引量:1
  • 8Kim M, Levy EI, Meng H, et al. Quantification of hemodynamic changes induced by virtual placement of multiple stent across a wide-necked basilar trunk aneurysm. Neurosurgery, 2007, 61 : 1305-1312. 被引量:1
  • 9Canton G, Levy I, Lasheras JC. Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms. J Neurosurg,2005,103:891-902. 被引量:1
  • 10Kallmes DF, Ding YH, Dai D, et al. A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms. Am J Neuroradiol, 9009, 30 : 1153-1158. 被引量:1

共引文献23

同被引文献43

  • 1王瑄,李占斌,丁文峰,刘峰.土壤剥蚀率与水流剪切力关系试验研究[J].沈阳农业大学学报,2004,35(5):592-594. 被引量:6
  • 2陈力,刘青泉,李家春.坡面细沟侵蚀的冲刷试验研究[J].水动力学研究与进展(A辑),2005,20(6):761-766. 被引量:19
  • 3翟水亭,李天晓,宗登伟,曹会存,王子亮,白卫星,刘建文.3D DSA在颅内动脉瘤介入诊疗中的应用价值[J].实用放射学杂志,2006,22(8):982-985. 被引量:4
  • 4王瑄,李占斌,郑良勇.土壤剥蚀率与水流剪切力关系室内模拟试验[J].沈阳农业大学学报,2007,38(4):577-580. 被引量:14
  • 5Yoon W. Current update on the randomized controlled trials of in-tracranial aneurysms[J]. Neurointervention, 2011, 6(1): 1-5. 被引量:1
  • 6Anxionnat R, Bracard S, Ducrocq X, et al. Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment[J]. Radiology, 2001, 218(3): 799-808. 被引量:1
  • 7Schueler BA, Kallmes DF, Cloft HJ. 3D cerebral angiograpby: radiation dose comparison with digital subtraction angiography[J]. AJNR Am J Neuroradiol, 200,5, 26(8): 1898- 1901. 被引量:1
  • 8Piotin M, Gailloud P, Bidaut L, et al. CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study[J]. Neuroradiology, 2003, 45(6): 404-409. 被引量:1
  • 9Loh Y, McArthur DL, Tateshima S, et al. Safety of intracranial endovascular aneurysm therapy using 3-dimensional rotational angiography: a single center experience[J]. Surg Neurol, 2008, 69(2): 158 -163. 被引量:1
  • 10Hayakawa M, Murayama Y, Duckwiler GR, et al. Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system[J].J Neuro Surg, 2000, 93(4): 561-568. 被引量:1

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部