摘要
和水力除渣方式相比,干式排渣有结构简单、节水、干渣经济价值高等优点。将原水力除渣改为干式排渣后,锅炉的运行特性会发生变化,通过对干式排渣运行特性的全面分析和优化,找出积极因素和负面影响,为除渣系统的改造和运行提供参考。
Comparing to the discharging slag by water, the dry bottom ash handling system has many advantages such as simple structure, water conserving, more useful. When the bottom ash system has been changed from water mode to dry mode, the operating characteristics of boiler will be varied, which is analyzed and optimized in detailed. Positive and negative impacts are found, which can be referred when the bottom ash system revised and boiler operating.
出处
《山东电力技术》
2012年第1期57-60,共4页
Shandong Electric Power
关键词
电站锅炉
水力除渣
干式排渣
运行特性
分析优化
power station boiler
discharging slag by water
dry bottom ash handling system
operating characteristic
analyzed and optimized