期刊文献+

电子耳蜗声调信息的电刺激编码的改进研究 被引量:5

Improvement of electric-stimulus rate encoding algorithm based on Mandarin tonal information in cochlear implant
下载PDF
导出
摘要 电子耳蜗现有产品所采用的语音处理算法以传递语音信号的幅度信息为基础,丢失了声调信息,因此造成我国电子耳蜗植入者对声调的识别还存在困难。声调信息主要蕴涵在语音基频中,在电刺激下,为了提高基频检测的准确性进而提高对声调的识别率,并对刺激速率进行准确选择,在前期提出的9度速率电刺激编码策略的基础上,通过自相关算法及平均幅度差函数的联合使用来提高基频提取的准确性,同时采用动态步长搜索解决分类饱和的问题,从而实现对刺激速率的准确选择。结果显示本研究提高了基频提取的准确性和对刺激速率进行动态选择的准确性。 Present cochlear implant products are based on the algorithms that mainly transmit the amplitude informa- tion of the speech signal, while the tonal information is lost. Thus it is difficult for the Chinese implant carrier to identify tonal information of mandarin. Tonal information is implicated in fundamental frequency. In electric-stimu- lus, in order to improve the detection accuracy of fundamental frequency and select the stimulation rate accurately, an algorithm that combines the autocorrelation function and average magnitude difference is proposed in this paper. At the same time, a dynamic step searching method is introduced to solve the saturation problem and accurately clas- sify the levels of electric-stimulus rate based on the 9-level electric-stimulus encoding algorithm we proposed earlier. Study results show that the detection accuracy of fundamental frequency is improved and the selection of electric- stimulus rate becomes more accurate.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2012年第2期271-278,共8页 Chinese Journal of Scientific Instrument
基金 国家"十一五"科技支撑计划(2008BAI50B08) 国家自然科学基金(60871083) 北京市自然科学基金(3082012)资助项目
关键词 电子耳蜗 声调 基频提取 动态分类 cochlear implant tone fundamental frequency detection dynamic classification
  • 相关文献

参考文献10

二级参考文献70

共引文献90

同被引文献82

  • 1马春排,李天钢,李自毅,周秦武.生物医学工程实践教学体系的建设[J].实验室研究与探索,2010,29(4):103-105. 被引量:35
  • 2冯波,翁杰,黄楠,屈树新,李孝红.结合学科特点和自身优势建立生物医学工程本科专业实验教学体系[J].实验技术与管理,2006,23(10):15-17. 被引量:14
  • 3JOHN E F, DAVID R. Wireless communication with im- planted medical devices using the conductive properties of the body [ J ]. Expert Rev. Med. Devices, 2011,8 (4) : 423-429. 被引量:1
  • 4VELLISTE M, PEREL S, SPALDING M C, et al. Cortical control of a prosthetic arm for self-feeding [ J ]. Nature, 2008,453 (7198) : 1098-1101. 被引量:1
  • 5MORITZ C T,PERLMUTFER S I,FETZ E E. Direct con- trol of paralysed muscles by cortical neurons [ J ]. Nature, 2008,456(7222) : 639-642. 被引量:1
  • 6BENABID A L, CHABARDS S, M1TROFANIS J, et al. Deep brain stimulation of the subthalamic nucleus for thetreatment of Parkinson's disease [ J ]. Lancet Neurol, 2009,8 ( 1 ) : 67-81. 被引量:1
  • 7HAUSER R G, KATS1YIANNIS W T, GORN1CK C C, et al. Deaths and cardiovascular injuries due to device-assis- ted implantable cardioverter-defibrillator and pacemaker lead extraction [ J ]. Europace, 2010,12 ( 3 ) : 395-401. 被引量:1
  • 8LOEB G E, RICHMOND F JR, BAKER L L,et al. The BION devices: injectable interfaces with peripheral nerves and muscles [ J ] Neurosurg. Focus, 2006,20 ( 5 ) : 1-Q. 被引量:1
  • 9ORLOV M V,SZOMBATHY T,CHAUDHRY G M,et al. Remote surveillance of implantable cardiac devices [ J ]. PACE ,2009,32( 7 ) : 928-939. 被引量:1
  • 10DORIN P. Wireless communication systems for implant- able medical devices [ J ]. IEEE Engineering in Medicine and Biology Magazine,2008,27(2) : 96-101. 被引量:1

引证文献5

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部